We are saddened as our lives have been forever impacted by the Covid-19 pandemic. Everyone has now experienced the impact of Coivd-19 whether directly by the disease, by economic hardship, or as one of our brave medical workers and essential workers on the frontlines worked to exhaustion. And some of you are impacted in all manners. Our thoughts are with you!

Businesses and social gathering places are reopening even though we are still at the very beginning of the Coronavirus pandemic. Guidelines for “reopening” are scattered, conflicting and confused. Primary guidelines to not gather in groups of more than 10, stay 6 feet apart, wear facemasks (to protect others, not you), not touch your face, and wash regularly are important, but there is much more to reopening safely.

Our March and April Covid-19 articles discuss airborne disease transmission characteristics and reducing disease transmission through “social distancing”. After two months of social distancing in the US, business and social interactions are increasing. Business owners have been left in a state of confusion, and are sometimes instituting practices that enhance rather than inhibit disease transmission. For example, one restauranteur in Ohio installed transparent plastic sheets around each table, reducing ventilation air flow and increasing fomite (contagion coated objects) surface area.

Our practical and effective guidelines for inhibiting the spread of airborne contagions will also refresh your brain and improve sleep. And, with an efficient smart ventilation system automatically managing healthy air, you’ll be freed from the continual weight of stress and worry.

Build Equinox Covid-19 Recommendations

For homes, business, and public gathering places:

For businesses and public gathering places:

Effective ventilation should be on the frontline of defense to protect our homes, schools, and businesses from Covid-19. Current ventilation practices do not provide sufficient protection against disease transmission. We use a simple example to demonstrate the inadequacy current ventilation standards, and how CERV2 smart ventilation automatically meets a person’s fresh air needs.

Background

Protection from contagions has been a primary objective of our CERV ventilation technology from the beginning. Read our February 2017 article discussing how smart ventilation reduces the impact of influenza and colds. Why is the state of ventilation so focused on “saving” energy in lieu of improving our health? Our health is much more valuable than energy, especially in this day and age of affordable renewable energy. Current “odor” based ventilation standards are making us sick, stupid and tired. It is time to think beyond energy and to put building occupant health, comfort and security at the forefront of building design priorities, with energy as an important constraint. The good news is that you can have your cake and eat it, too, as demonstrated by our plus-zero Equinox House project, and our 4500 square foot, net zero Build Equinox business headquarters.

Keeping indoor carbon dioxide concentration levels below 800ppm, especially during the pandemic, is crucial for reducing the airborne spread of Covid-19. Our March newsletter provided a detailed discussion of the relationship between indoor carbon dioxide concentration level and concentration of a contagion. The amount of an airborne contagion, such as the SARS-CoV-2 virus, is directly related to a contagious individual “shedding” the virus through breathing, speaking, coughing and sneezing. Increased fresh air ventilation, filtration of recirculation air, and additional sanitizing using UVGI (ultraviolet germicidal irradiation) or other disinfectants significantly reduce contagion concentration, and therefore, the probability that one becomes infected. References included at the end of this article lists journal articles with current Covid-19 research, and other relevant information on respiratory viruses, their transmission, survival, and control.

An infectious “dose” of a contagion is defined as a “quanta”, with one quanta resulting in a 63% probability (probability = 1-exp(-q), where q=quanta) of infection. There are many possible contagion transmission paths as a virus leaves its host to find another susceptible person. With Covid-19, touching the eyes, nose, or mouth after touching a contaminated surface (“fomite”) may also deliver doses of infection, although the CDC has reduced their emphasis on this infection pathway while further increasing their emphasis of direct infection spread through the air.

Figure 1 shows how infection probability is related to indoor carbon dioxide concentration and time spent indoors with an infected person. The example assumes 4 occupants with 1 infectious occupant. Minimizing time is important as well as fresh air dilution of contagion and carbon dioxide. Note that for 4 people, 25% of carbon dioxide in the room (above ambient conditions) is exhaled from the infected person. If there are 2 occupants with one infectious and the other susceptible, the quanta of infectious doses would be twice as great at the same carbon dioxide concentration. Therefore, the exposure time curves would be reduced in half (ie, a half hour exposure results in the same infection probability as a 1 hour exposure at a given carbon dioxide concentration).

Ventilation should be a weapon against disease spread, however, poorly designed, poorly installed, and poorly operated systems can be enhancers rather than inhibitors of disease spread. We compare effective ventilation versus ineffective ventilation with another example. Our example is a 1000ft2 residence with 8ft ceilings, such as a multi-family apartment or manufactured (mobile) home. The home has 2 bedrooms with four occupants. We choose this residence because it represents the area in which current ventilation standards are most deficient. Our example is also representative of housing in dense, urban environments where Covid-19’s spread has been devastating.

Current residential ventilation standards are deficient in two important areas: insufficient fresh air ventilation per person and lack of filtered recirculation air. Our Smart Ventilation and Smart Air Distribution reports cover these important aspects of ventilation design, and how smart ventilation allows one to simultaneously be more energy efficient and healthy. Current ASHRAE 62.2-2019 standards specify 52.5cfm for the example residence, or 13cfm per person. EPA indoor airPLUS allows the outdated and horribly insufficient ASHRAE62.2-2010 standard that specifies 32.5cfm, or 8cfm per person. Passive House ventilation standards, both PHI and PHIUS, allow 0.3ACH, or 40cfm (10cfm per person).

Build Equinox has recommended 40cfm per person for several years. Why? Three reasons:

1) Research shows that sick days are reduced by 40% by doubling current rule-of-thumb 20cfm per person to 40cfm person, equivalent to the effectiveness of the flu vaccine

2) A study from Harvard’s TH Chan School of Public Health estimates increasing ventilation from 20cfm to 40cfm per person improves cognition performance with an increased human productivity value of $6500 per person relative to only $50 per person utility cost increase

3) A study by the Danish Technical University, a leading center for healthy indoor environment research, demonstrates that our recommended fresh air level improves sleep and next day activity performance

The real question is why anyone would choose to live in a home or visit buildings with inadequate fresh air that promotes sickness, degrades brain function, and disturbs sleep?? Current ventilation standards are based on odor, not health, and lack of odor is not an indicator of healthy air.

Build Equinox considers filtered recirculation of indoor air as an essential feature of ventilation systems. Many high performance home standards, such as Passive House International, fail to understand the importance of air recirculation. “Sufficient” fresh air as described by PHI is not healthy air. We need exceptional indoor environments and recirculation is an important part. Recirculation is important for 3 reasons:

As discussed in our article on particulates, “The Perfect Dust Storm”, most particulates in today’s homes are generated indoors from cooking and human activities. A home without recirculation will have much higher particulate levels than one with filtered recirculation. A contagion’s airborne concentration, such as the SARS-CoV-2 virus, are significantly reduced with filtered recirculation, too.

Universal Guidelines 1, 2, and 3:

Our first 3 guidelines for home and public spaces (schools, businesses, restaurants and other indoor public gathering spaces) reduce the probability of infection by reducing contagion concentration in the air through higher fresh air ventilation rates (40cfm per person), filtered recirculation of indoor air, and UVGI sanitizing of recirculation air.

Professor Stephens and colleagues at the Illinois Institute of Technology published an article [12] examining the spread of bacteria and virus throughout a residential scale test facility. A respiration and “cough” machine introduced non-lethal bacteria and virus particles into the test space. A central HVAC system recirculated air throughout the residence, with air samplers and “settle” plates placed in different regions of the residence.

An interesting and important difference between bacteria loaded droplet tests and viral particle loaded tests is the dramatic difference in droplet deposition characteristics. Bacteria, with a characteristic size similar to respiratory droplets, alters droplet sizes and results in droplets being heavily deposited near the respiration machine. Viral loaded droplets have much smaller droplet sizes and did not settle near (0.5m) the droplet generation machine. The region of highest viral mass was found to be 3 meters (~10feet) away from the respiration source! Significant viral mass was also measured 5m away from the respiration/coughing source while a negligible amount of viral mass was found near the respiration machine. The authors reported that MERV8 filtration of recirculation air did not noticeably reduce viral loadings in the residence in comparison to unfiltered recirculation air. MERV11 and MERV16 filters did effectively capture viral mass by 85 to 95% within the residence. We therefore estimate that a MERV13 filter can similarly remove 90% of viral particulates.

Figure 2 compares the probability of Covid-19 disease transmission assuming one infected person shedding the virus at 100quanta per hour. Three susceptible people are in the building with the infectious person. Spending 8 hours or more with an infected person under EPA indoor airPLUS (ASHRAE62.2-2010), Passive House (0.3ACH), and current ASHRAE62.2-2019 ventilation standards is very likely (>95% probability) to result in the other 3 people becoming infected. As soon as a second person is infected and shedding virus, the probability of infecting others jumps higher.

Increasing fresh air ventilation to our recommended 40cfm per person (160cfm total fresh air) lowers infection probability to 75%. Operating the ventilation system with an air recirculation rate of 90cfm through a MERV13 filter further decreases infection probability during 8 hours of co-occupation to 60%. Note that the 40% reduction in disease transmission probability from today’s standard practice to our suggested fresh air recommendation is in line with the sick day reduction determine by Milton and colleagues [6] in their study of over 3000 employees in several building environments of varying ventilation and recirculation rates in which they demonstrated a 40% sick day reduction.

Adding UVGI to recirculation air can further reduce contagions. ASHRAE’s recent UVGI webinar by Professor William Bahnfleth of Penn State, an international expert in UVGI, stated that 0.02WUVGI per cfm of air flow is sufficient for 85% “single pass kill” efficiency. For our example house with 160cfm of fresh air ventilation, 3.2WUVGI of radiant power is needed, which is approximately 13W of electrical power, assuming a 25% conversion efficiency to UV radiation. Professor Bahnfleth, who is also a former ASHRAE President, is a leader promoting the importance of exceptional rather than sufficient indoor environments (see Figure 3, and watch our 2016 webinar on smart ventilation).

Figure 2 shows an estimated UVGI reduction of infection probability from 60% for 40cfm per person with 90cfm of MERV13 filtered recirculation air to 50%. Operating a 13W UV lamp continuously requires 114kWh of electric energy, or about $14 per year of solar supplied energy assuming 12 cents per kWh. Reducing the probability of someone in your household catching a cold, the flu or Covid-19 by spending approximately $1 per month seems like something to consider even if it downgrades your home’s energy certification rating.

Business and Public Gathering Guidelines 4, 5, and 6:

Additional protections are recommended for work, schools, restaurants and other public gathering places in which you have increased uncertainty of interacting with infectious persons. The insidious nature of Covid-19 asymptomatically affecting people makes it difficult to detect and contain.

In addition to using UVGI for sanitizing ventilation and recirculation air, UVGI lamp fixtures are available that mount on ceilings and walls. The lamps operate at a sufficiently high power to sanitize surfaces in a room, such as table, desks, shelves, etc. These systems are primarily used in medical facilities, however, perhaps incorporation into gathering places such as restaurants and businesses with large public turnover (eg, Motor Vehicle offices) could benefit from their usage. The lights are operated during unoccupied periods, typically at night. Robotic UVGI units are now available that monitor UV dosage delivered to different surfaces. A study from one medical facility reported a 10-fold drop in contagions on surfaces that had been sterilized with a disinfectant [18].

Wearing a cloth mask in public places (and at home when you suspect you may be infected) significantly reduces droplets released from respiration, talking, coughing and sneezing. A 50% reduction of released contagion is very significant, as shown in Figure 4. The example building described previously (4 occupants with one infectious occupant) is modeled in this figure. Standard building ventilation practice cases continue to have 90% level probability of infection transmission with 8 hours of occupation while increased fresh air with filtered and UV irradiated air reducing 8 hour infection probability to below 40%.

Our final recommendation for protecting you against infection is to stay much farther away than 6 feet from unmasked, unknown persons. Think of how far you can smell smoke from a cigar to gauge a safe distance, and if possible detect air flow direction (outside, too), and move upwind. Perhaps we need to request “masked seating” in restaurants, similar to non-smoking sections of the recent past.

Practical Implementation of Guidelines:

The connection between carbon dioxide concentration and contagion concentration makes verification of fresh air flow simple. We recommend that you acquire a good quality carbon dioxide sensor with 30ppm accuracy, which costs $200 to $300. Less expensive units are available, however accuracy and stability tend to be less reliable. Figure 5 shows two handheld CO2 instruments. The red one costs $260 and the white one costs $500 (we’ve had it for 10 years with lots of use). Maybe share the cost with some friends or co-workers, and use it to map out building air quality in a variety of places that you regularly visit. If carbon dioxide is above 800ppm, re-think whether you want to stay in that indoor space. Remember that today’s building ventilation standards are based on 1000 to 1200ppm, so don’t be surprised at finding concentration levels above 800ppm. At the same time, you should find many spaces with 800ppm or less because ventilation designers often make conservative estimates as to occupancy levels, resulting in higher ventilation levels.

And then, there are those places with poor air quality, such as commercial airlines. Yes, the CEOs of several airlines have been on television assuring us that their fleet operates with 20 air changes per hour and recirculates air through a HEPA filter. Figure 6 shows a different reality with CO2 concentration measurements on a flight I took from Philly to Burlington Vermont. Obviously, fresh air per person was very low, and I caught the flu. Trust, but verify!

CERV2 Smart Ventilation:

Equinox House, our Zero-Plus demonstration home in Urbana Illinois (and Ty and Debs’ house) normally operates with CERV CO2 and total VOC setpoints of 850ppm, however, at the beginning of March, we switched IAQ setpoints to 650ppm. Figure 7 shows indoor air quality at excellent levels (both CO2 and total VOCs), along with stable, comfortable indoor temperature and humidity. Although climatic loads on average are low during the “swing seasons”, maintaining stable comfort conditions can be difficult. If you would like to look at Equinox House data over the past 4 years, check out live Equinox House control settings on the front page of our website under “Take Control”. Learn how to design an economical, high performance, and healthy house by following our seven steps to net zero design webinar.

And, stay tuned for an upcoming announcement of CERV-UV! A new option for CERV2 owners.

References

1) KP Talaro, A Talaro, Foundations in Microbiology, 3rd Ed, McGraw Hill, 1999
2) M Moriyama, WJ Hugentobler, A Iwasaki, “Seasonality of Respiratory Viral Infections”, Annu.Rev.Virol.2020.7:2.1–2.19, Mar 2020
3) James Holland Jones, “Notes on R0, class notes”, Dept of Anthropology, Stanford University, May 2007
4) “What you should know about COVID-19 to protect yourself and others”, CDC Factsheet, cdc.gov/coronavirus
5) “Modes of transmission of virus causing COVID-19: implications for IPC precaution recommendations”, World Health Organization, scientific brief, Mar 29, 2020
6) DK Milton, PM Glencross, MD Walters, “Risk of Sick Leave Associated with Outdoor Air Supply, Humidification, and Complaints”, Indoor Air, 2000, 10: pp 212-221
7) TA Myatt, J Staudenmayer, K Adams, M Walters, SN Rudnick, DK Milton, “A Study of Indoor Carbon Dioxide Levels and Sick Leave Among Office Workers”, Environmental Health: A Global Access Science Source 2002, 1
8) AC Lowen, S Mubareka, J Steel, P Palese, “Influenza Virus Transmission Is Dependent on Relative Humidity and Temperature”,PLoS Pathogens, October 2007, Volume 3,Issue 10
9) LC Marr, JW Tang, J Van Mullekom, SS Lakdawala, “Mechanistic Insights into the Effect of Humidity on Airborne Influenza Virus Survival, Transmission and Incidence”, JR Society Interface 16: 20180298, 2019
10) KA Kormuth, K Lin, AJ Prussin, EP Vejerano, AJ Tiwari, SS Cox, MM Myerburg, SS Lakdawala, LC Marr, “Influenza Virus Infectivity Is Retained in Aerosols and Droplets Independent of Relative Humidity”, J Infectious Diseases, 2018:218 September
11) L Bourouiba, “Turbulent Gas Clouds and Respiratory Pathogen Emissions Potential Implications for Reducing Transmission of COVID-19”, JAMA Published online March 26,2020, pE1
12) SA Kunkel, P Azimi, H Zhao, BC Stark, B Stephens, “Quantifying the size- resolved dynamics of indoor bioaerosol transport and control”, Indoor Air. 2017;27:977–987
13) N van Doremalen, T Bushmaker, DH Morris, MG Holbrook, A Gamble, BN Williamson, A Tamin, JL Harcourt, NJ Thornburg, SI Gerber, JO Lloyd-Smith, E de Wit, VJ Munster, “Aerosol and surface stability of HCoV-19 (SARS-CoV-2) compared to SARS-CoV-1”, medRxiv preprint (not peer-reviewed) https://doi.org/10.1101/2020.03.09.20033217doi
14) Lu J, Gu J, Li K, Xu C, Su W, Lai Z, et al. “COVID-19 outbreak associated with air conditioning in restaurant, Guangzhou, China, 2020”, Emerg Infect Dis. 2020 Jul, https://doi.org/10.3201/eid2607.200764
15) JL Santarpia, DN Rivera, V Herrera, MJ Morwitzer, H Creager, GW Santarpia, KK Crown, DM Brett-Major, E Schnaubelt, MJ Broadhurst, JV Lawler, St. Patrick Reid, JJ Lowe, “Transmission Potential of SARS-CoV-2 in Viral Shedding Observed at the University of Nebraska Medical Center”, medRxiv preprint, https://doi.org/10.1101/2020.03.23.20039446doi
16) LA Anchordoqui, EM Chudnovsky, “A physicist view of the airborne infection”, arXiv:2003.13689v1 [physics.pop-ph] 30 Mar 2020
17) SN Rudnick, DK Milton, “Risk of indoor airborne infection transmission estimated from carbon dioxide concentration”, Indoor Air, 2003; 13: 237–245
18) Titus Wong, Tracey Woznow, Mike Petrie, Elena Murzello, Allison Muniak, Amin Kadora, Elizabeth Bryce, “Postdischarge decontamination of MRSA, VRE, and Clostridium difficile isolation rooms using 2 commercially available automated ultraviolet-C–emitting devices”, American Journal of Infection Control, Vol 44 (2016), pp 416-420

Filter
DateTitle
Dec 20, 2024 Spotlight – Taylorville High School / Pretty Good House Status Update 7: Mechanicals Installation 20241220
Oct 31, 2024 Spotlight – Greenshell home in Northbrook, IL 20241031
Oct 31, 2024 News – Neurodegeneration Linked to Short Term Infections 20241031
Sep 25, 2024 Tech – Early Airborne Infection Detection and Alert System 20240925
Sep 25, 2024 Spotlight – Heart of the Building (Video): John Avenson Residential Renovation Project 20240925
Aug 28, 2024 Events – Energy and Efficiency with Emily Podcast ft. Matt Blomquist and Ty Newell Tags: Comfort, Net Zero, New Construction 20240828
Aug 19, 2024 Spotlight – CERV-1000 Medical Clinic Visit Tags: CERV 1000, Renovation, Ventilation 20240819
Aug 15, 2024 Featured Article – Healthy Air Training is Important for Olympic Champions and the Rest of Us Tags: Health, Indoor Air Quality, Particulates 20240815
Jul 25, 2024 Events – “The Weekly Investment Podcast” feat. Ty Newell Tags: Comfort, Health 20240725
Jul 25, 2024 Tech – Positive Pressure: Flow Balancing of Duct Networks Tags: CERV 1000, Ducting 20240725
Jun 20, 2024 Tech – It is Artificial, but is it Intelligent? Tags: Indoor Air Quality 20240620
Jun 20, 2024 Featured Article – Positive Pressure: Prepare Yourself for Wildfire Season! Tags: Indoor Air Quality, Particulates 20240620
May 26, 2024 Events – Free CEU Webinar: What’s up with the Taylorville High, Net Zero, Pretty Good House Student Build? (June 26th) Tags: Net Zero, New Construction, Webinar 20240526
May 26, 2024 Spotlight – Taylorville High School / Pretty Good House Status Update 6: Wood Fiber Insulation and Steel Roofing Tags: Net Zero, New Construction 20240526
May 26, 2024 Featured Article – All in the Family (Coulliard Solar Foundation CERV-1000 Installation) Tags: CERV 1000, Solar 20240526
Apr 26, 2024 Events – Free CEU Webinar: Happy Boolo LEED & Zero Energy Renovation Home Tour (May 1st) Tags: Renovation, Webinar 20240426
Apr 26, 2024 News – University of Illinois and Build Equinox Particulate Research Published Tags: Particulates, Report 20240426
Apr 26, 2024 Spotlight – Taylorville High School / Pretty Good House Status Update 5: Robust & Smart Ventilation and Comfort Conditioning System Design for High Performance Homes Tags: Comfort, Net Zero, New Construction 20240426
Mar 22, 2024 Spotlight – Lakeside Net Zero LEED Platinum Passive House Tags: Net Zero, New Construction, Passive House 20240322
Mar 22, 2024 Featured Article – Breathing New Life: CERV2 Retrofits in Metropolitan Milwaukee Homes Tags: CERV, Indoor Air Quality, Renovation 20240322
Feb 29, 2024 Featured Article – Colorado Public Radio interview with CERV Homeowner John Avenson 20240229
Feb 28, 2024 Spotlight – Taylorville High School / Pretty Good House Status Update 4: Manual D (Duct Design) Tags: Ducting, New Construction 20240228
Jan 30, 2024 Featured Article – Count on the CERV-1000 to Keep Classrooms Healthy and Comfortable in Extreme Cold Weather Tags: CERV 1000, Health, Indoor Air Quality 20240130
Dec 20, 2023 Spotlight – Taylorville High School PGH Update 3: Manual J Load Calculations Tags: Comfort, Energy Efficiency, New Construction 20231220
Dec 20, 2023 Featured Article – Don’t Carbonize People to De-carbonize Buildings! Tags: Energy Efficiency 20231220
Nov 15, 2023 Spotlight – Taylorville High School / Pretty Good House Status Update 2: Energy and Comfort Tags: Comfort, Energy Efficiency, New Construction 20231115
Nov 15, 2023 Featured Article – Distillery North Leading the Charge to Meet ASHRAE 241 Tags: Renovation 20231115
Oct 20, 2023 Featured Article – Building a Strong Foundation: Taylorville High School Pretty Good House Project Tags: New Construction 20231020
Oct 3, 2023 Events – Free Video: An All-in-One Solution for Creating Healthy, Comfortable and Energy Efficient Classrooms Tags: CERV 1000, Health, Indoor Air Quality, Webinar 20231003
Sep 26, 2023 Featured Article – CERV-1000 Creates a Healthy, Productive, Comfortable, Decarbonized and Energy Efficient Classroom! Tags: CERV 1000, Health, Indoor Air Quality 20230926
Sep 26, 2023 Spotlight – Taylorville High School / Pretty Good House Collaboration Project Tags: New Construction 20230926
Sep 26, 2023 Event – Better Building Ventilation: Demand Control & Conditioning – Free CEUS (Sep 27) Tags: CERV, Indoor Air Quality, Webinar 20230926
Sep 26, 2023 Event – Maine Indoor Air Quality Council: IAQ and Energy 2023 (Portland, ME, Oct 30) Tags: Conference, Indoor Air Quality 20230926
Sep 26, 2023 Event – Illinois Association of School Boards: Joint Annual Conference (Chicago, IL, Nov 17-19) Tags: CERV 1000, Conference 20230926
Jul 26, 2023 Analysis – Where the Wildfire Smoke Goes (Understanding Particulate Management) Tags: Particulates 20230726
Jul 26, 2023 Featured Article – World’s Healthiest Classroom? CERV-1000 Installed and Ready for Action! Tags: CERV 1000, Indoor Air Quality 20230726
Jun 27, 2023 Featured Article – IAQ Standards Summary & Comparison Tags: CO2, Indoor Air Quality, Particulates, VOC 20230627
Jun 27, 2023 Breaking News! – ASHRAE Standard 241 “Control of Infectious Aerosols” Approved Tags: ASHRAE, Health, Indoor Air Quality 20230627
Jun 27, 2023 Spotlight – Brixham Hat Trick: Creating Healthy, Energy Efficient and Sustainable Schools in Maine’s Challenging Climate Tags: Indoor Air Quality, Renovation 20230627
May 30, 2023 Featured Article – Healthy Indoor Air Quality Standards: Carbon Monoxide & Radon Tags: Indoor Air Quality 20230530
May 30, 2023 Tech: ASHRAE 241P – The Beginning of a Healthy Air Revolution? Tags: ASHRAE, Health, Indoor Air Quality 20230530
May 30, 2023 Spotlight – University of Wyoming Solar Decathlon Team Wins 1st Place in Comfort and Environmental Quality with the CERV2! Tags: Comfort, New Construction, Solar Decathlon 20230530
Apr 28, 2023 Spotlight – Better Building by Design & NESEA: Barnstorming New England Tags: Conference 20230428
Apr 27, 2023 Introducing the CERV–1000 – Automated IAQ & Comfort Control for Classrooms, Restaurants, and Other High Occupant Density Spaces. Tags: CERV 1000 20230427
Apr 27, 2023 Featured Article – Healthy Indoor Air Quality Standards: Particulates (PC0.3 and PM10) Tags: Indoor Air Quality, Particulates 20230427
Mar 27, 2023 Featured Article – Healthy Indoor Air Quality Standards: Volatile Organic Compounds (VOCs) Tags: Indoor Air Quality, VOC 20230327
Feb 27, 2023 Events – Creating Healthy, Decarbonized Classrooms (Building Energy Boston, Mar 29) Tags: CERV 1000, Conference 20230227
Feb 27, 2023 Events – Better Buildings by Design (VT, Apr 5-6) Tags: Conference 20230227
Feb 27, 2023 Education – The Foundation for A Sustainable Future: Wellesley Public School “House Unplugged” Project 20230227
Feb 27, 2023 Featured Article – Healthy Indoor Air Quality Standards: Carbon Dioxide (CO2) Tags: CO2, Indoor Air Quality 20230227
Jan 26, 2023 News – What’s New in IAQ Tags: CO2, Indoor Air Quality, Particulates, VOC 20230126
Jan 26, 2023 Spotlight – Pipsqueak Passive House Makes a Big Noise Tags: New Construction, Passive House 20230126
Jan 26, 2023 Featured Article – Build Equinox Announces Healthy Indoor Air Quality Standard for the New Year! Tags: CO2, Indoor Air Quality, Particulates, VOC 20230126
Dec 30, 2022 Featured Article – Tis the Season to be Jolly? Ventilation, Inflammation and Mojo Tags: Health 20221230
Dec 30, 2022 News – Optimism for a New Year! 20221230
Nov 29, 2022 Featured Article – Fresh Air Ventilation Requirements for Pets Tags: Indoor Air Quality 20221129
Nov 29, 2022 Opinion – Are We Moving Too Fast to a Sustainable Future?  NO! Tags: Energy Efficiency 20221129
Oct 26, 2022 Vox: Our Buildings are Making Us Sick Tags: Health, Indoor Air Quality 20221026
Oct 21, 2022 Events – Visit Us at PhiusCon 2022 (Chicago, October 26-28)! Tags: Conference, Passive House 20221021
Oct 21, 2022 Tech – High SEER A/C: Higher Ratings at the Expense of Comfort Tags: Comfort, Dehumidification, Energy Efficiency, Heat Pump, Humidity 20221021
Oct 21, 2022 Featured Article – We Have Smelled the Polluters, and They are Us! Tags: CO2, Indoor Air Quality, VOC 20221021
Sep 30, 2022 Featured Article – ASHRAE (finally) Clarifies Ventilation Standard 62 IS NOT an Indoor Air Quality Standard Tags: ASHRAE, Indoor Air Quality 20220930
Sep 30, 2022 Tech – Smoking Gun: Fomite Aerosol Hypothesis Tags: Particulates 20220930
Aug 22, 2022 New Product – Level Up Your Particulate Filtration with MERV 14! Tags: Filters 20220822
Aug 22, 2022 Tech – Bright Idea! Wireless Switch Drops 20220822
Aug 22, 2022 Featured Article – Getting Fit… or Getting Sick? Tags: Health, Indoor Air Quality 20220822
Jul 20, 2022 Events – 2022 ASHRAE Annual Conference Tags: ASHRAE, Conference 20220720
Jul 20, 2022 Featured Article – 10th Anniversary of The Sun Catcher’s Journey! Tags: Solar 20220720
Jun 30, 2022 Featured Article – Radiant Heating and Cooling in High Performance Homes Tags: Comfort 20220630
Jun 30, 2022 Events – Healthy IAQ & Smart Ventilation Guidelines (July 27) Tags: Indoor Air Quality, Webinar 20220630
Jun 29, 2022 Spotlight – Frank Lloyd Wright: The Wasmuth Portfolio 20220629
May 23, 2022 Featured Article – Indoor Filters are Alive! Tags: Filters, UV 20220523
May 23, 2022 Tech – CERV2 Airflow and Duct Design Tags: CERV, Ducting 20220523
May 21, 2022 Events – Healthy IAQ & Smart Vent Guidelines (Video + PDF) Tags: Indoor Air Quality, Webinar 20220521
Apr 27, 2022 The Radon Puzzle – Smart Ventilation and Filtration Impacts on Radon Tags: Radon 20220427
Apr 27, 2022 Tech – New Pure Carbon Filters with 3x Carbon! Tags: Filters 20220427
Mar 28, 2022 Tech – CERV-UV: Ultimate Ultraviolet! Tags: CERV, UV 20220328
Mar 28, 2022 Review – Geothermal Alliance of Illinois Conference 20220328
Mar 28, 2022 Featured Article – Introducing Victor Niño as Build Equinox Director of Business Development 20220328
Feb 22, 2022 Tech Announcement – We’re Particular About Particulates! Tags: Particulates 20220222
Feb 22, 2022 Featured Article – Exciting New CERV2 Features and Options! Tags: CERV 20220222
Jan 27, 2022 Featured Article – Efficient, Smart Bathroom Ventilation with the CERV2 Tags: Bathroom 20220127
Jan 27, 2022 Review – Attending Large Venue Events – Go Illini, beat COVID! 20220127
Jan 27, 2022 Spotlight – Vermod in the News! 20220127
Dec 22, 2021 Featured Article – Filters are More Important (and Expensive) than Energy! Tags: Filters, Particulates 20211222
Dec 22, 2021 Spotlight – Sneak Peak: TBDA Decarbonization Project 20211222
Nov 15, 2021 Events – Two Talks in One Night at ASHRAE Madison (Dec. 13, 2021, CEUs available!) Tags: Webinar 20211115
Nov 15, 2021 Featured Article – Taylor CERV2+Ducted Mini Install (2.5 Year Follow-up) Tags: CERV, Renovation 20211115
Oct 25, 2021 Events – PHMass Passive House Virtual Symposium (Nov 3, 2021) Tags: Passive House, Webinar 20211025
Oct 25, 2021 Review – The Role of Global Air Pollution in Aging and Disease, by Professor Caleb Finch Tags: Health 20211025
Oct 25, 2021 Featured Article – Sustainable Schools Create a Sustainable Future Tags: CERV 1000 20211025
Sep 30, 2021 Events – PHIUScon 2021 Presentation: Human Centric Metrics for Improving Health, Comfort and Productivity Tags: Conference, Passive House 20210930
Sep 30, 2021 Featured Article – Kitchens are Exhausting! Tags: Kitchen 20210930
Sep 29, 2021 Events – Virtual Metro Denver Green Homes Tour 20210929
Aug 17, 2021 Opinion Article – ASHRAE, You’re Making Us Sick! Tags: ASHRAE 20210817
Aug 17, 2021 Featured Article – CERV2 Smart, Integrated, Supercharged Dehumidification Tags: CERV, Dehumidification 20210817
Jul 19, 2021 Events – CERV2 Smart-er Ventilation New Features & Product Demo (Video & Slides) Tags: CERV 20210719
Jul 19, 2021 Review – 5 Steps to Net Zero Multi-family Residence Renovation: Toronto Tags: Renovation 20210719
Jul 19, 2021 Featured Article – Test Chamber Pt. 2: VOCs! Tags: VOC 20210719
May 20, 2021 Tech – It’s Springtime and Aprilaire is in the Air! Tags: Dehumidification 20210520
May 18, 2021 Featured Article – Alexa, Meet the CERV 20210518
Apr 19, 2021 Spotlight – Illinois ADAPTHAUS Wins 1st Place in Comfort & Environmental Quality Tags: Comfort, Indoor Air Quality, Solar Decathlon 20210419
Apr 19, 2021 Events – Register for Building Energy Boston (Online)! May 5-7 Tags: Conference, Webinar 20210419
Apr 19, 2021 Featured Article – Broken Clocks Work Better than Today’s Ventilation Standards Tags: ASHRAE, Indoor Air Quality 20210419
Apr 19, 2021 Events – Upcoming Online Webinars and Conferences! Tags: Conference, Webinar 20210419
Mar 11, 2021 News – New Video, Booklet, and CERV2 Smart Options! Tags: CERV 20210311
Mar 10, 2021 Spotlight – CERV Installed in the UofI ADAPTHAUS Tags: CERV, Solar Decathlon 20210310
Mar 10, 2021 Events – Re-Opening Schools and Beyond Safely Webinars (3/23, 4/21, 4/22) Tags: Webinar 20210310
Mar 10, 2021 Featured Article – Human Value: Thinking Beyond Energy Tags: Energy Efficiency, Health 20210310
Feb 26, 2021 Spotlight – Dar-Lon Chan’s Journey to Sustainable Living 20210226
Feb 26, 2021 Featured Article – Covid Safe Space Calculator Tags: Health 20210226
Jan 29, 2021 Events – Efficiency Vermont Better Buildings by Design Conference (Feb 2-4) Tags: Conference 20210129
Jan 29, 2021 Spotlight – University of Illinois ADAPTHAUS becoming Reality Tags: Solar Decathlon 20210129
Jan 29, 2021 Featured Article – CERV2 Installed in Equinox House! Tags: CERV, Equinox House 20210129
Dec 21, 2020 Spotlight – Tour Bill Spohn’s New Modular Net Zero Home (CEUs available!) Tags: CERV, New Construction 20201221
Dec 21, 2020 Special Edition – Ventilation, Vaccination, Infection, and Luck. Covid-19 and the New Year Tags: Health 20201221
Dec 21, 2020 Featured Article – AWE: Air, Water, Energy Tags: Energy Efficiency, Indoor Air Quality, Water 20201221
Nov 17, 2020 Events – CERV2 Smart-er Ventilation Product Demo (Video + PDF) Tags: CERV, Webinar 20201117
Nov 16, 2020 Spotlight – New Lungs for a 101-Year-Old Home Pt.3: Heat Pump Water Heater! Tags: Renovation, Water 20201116
Nov 15, 2020 Featured Article – Equinox Meets the Needs / ASHRAE Solar ZEB Article 12 Tags: ASHRAE, Equinox House 20201115
Nov 12, 2020 Special Edition – Stay Safe this Holiday Season! Tags: Health 20201112
Oct 29, 2020 Spotlight – New Lungs for a 101-Year-Old Home Pt.2: Total HVAC Replacement! Tags: CERV, Comfort, Heat Pump, Renovation 20201029
Oct 28, 2020 Featured Article – Equinox House Performance / ASHRAE Solar ZEB Article 10 Tags: ASHRAE, Equinox House 20201028
Sep 22, 2020 Events – Michigan Residential Net Zero Energy Conference (Oct 20-22) Tags: Conference 20200922
Sep 22, 2020 News – CERV-UV Now Available for New Orders! Tags: CERV, UV 20200922
Sep 22, 2020 News – CERV-ICE Now in the iOS and Android App Stores! Tags: CERV 20200922
Sep 22, 2020 Featured Article – Solar Collection & Use / ASHRAE Solar ZEB Article 10 Tags: ASHRAE, Equinox House, Solar 20200922
Aug 17, 2020 Special Edition – Build Equinox Groundbreaking Research into COVID 19 Tags: Health 20200817
Aug 17, 2020 Events – SEDAC Webinar: Considerations, Best Practices, and Energy Implications for Reopening Critical Community Facilities in the Pandemic (Aug 18, 2020) Tags: Webinar 20200817
Aug 17, 2020 Featured Article – Comfort Conditioning & Indoor Air Quality / ASHRAE Solar ZEB Article 9 Tags: ASHRAE, Comfort, Equinox House, Indoor Air Quality 20200817
Aug 17, 2020 News – Building Science Podcast: “Ventilation & Virus Transmission Prevention” Tags: Health, Webinar 20200817
Aug 14, 2020 News – New HVAC School Podcast: “Advanced Ventilation w/ CERV2” (Watch/Listen) Tags: CERV, Webinar 20200814
Aug 12, 2020 Events – Free CEU Webinar: Can Building Science Help Us Slow COVID-19? (Sep 2, 2020) Tags: Health, Webinar 20200812
Jul 10, 2020 Special Edition – Covid-19 Update: Airborne Means AIRBORNE! Tags: Health 20200710
Jul 10, 2020 Featured Article – Appliances Power EVs / ASHRAE Solar ZEB Article 8 Tags: ASHRAE, Energy Efficiency, Equinox House 20200710
Jun 29, 2020 Events – Free New Webinar: Guidelines for Protecting Against COVID-19 (PDF + Slides) Tags: Health, Webinar 20200629
Jun 25, 2020 Featured Article – Designing a Thermally Massive Home/ASHRAE Solar ZEB Article 7 Tags: ASHRAE, Equinox House 20200625
Jun 25, 2020 Special Edition – Covid19 Status Report: We are at the Beginning of the Pandemic, Not the End Tags: Health 20200625
May 29, 2020 Spotlight – CERV Retrofit: New Lungs for a 101-Year-Old Home Tags: CERV, Renovation 20200529
May 29, 2020 Special Edition – Covid19 Status Report: Guidelines for Homes & Businesses Tags: Health 20200529
May 29, 2020 Featured Article – Ground Heat Transfer/ASHRAE Solar ZEB Article 6 Tags: ASHRAE, Equinox House 20200529
Apr 16, 2020 Events – Free CEU Webinar: Covid-19 Characteristics, Transmission, and Control (April 29th) Tags: Health, Webinar 20200416
Apr 16, 2020 Special Edition – Battling the Spread of Covid-19 Tags: Health, Report 20200416
Apr 16, 2020 Featured Article – Infiltration & Sealing/ASHRAE Solar ZEB Article 5 Tags: Energy Efficiency, Equinox House, Net Zero, Report 20200416
Apr 16, 2020 Spotlight – New Projects: 1930s CERV Retrofit & Mitsubishi Hyperheat Tags: CERV, Energy Efficiency, Heat Pump, Ventilation 20200416
Mar 13, 2020 Featured Article – Light and Delight/ASHRAE Solar ZEB Article 4 Tags: Comfort, Energy Efficiency, Equinox House, Solar 20200313
Mar 10, 2020 News – CERV Voted One of the Top 16 Coolest Things Made in Illinois! Tags: CERV 20200310
Mar 5, 2020 Special Edition – Fighting COVID-19 with Fresh Air Tags: Health, Indoor Air Quality, Report, Ventilation 20200305
Feb 24, 2020 Featured Article – Walls and Roof/ASHRAE Solar ZEB Article 3 Tags: Equinox House, Net Zero, Report, ZEROs 20200224
Feb 24, 2020 Tech – Magic-Box Mechanicals Tags: CERV, Comfort, Heat Pump, Ventilation 20200224
Feb 24, 2020 Events – Designing Exceptional Homes for Exceptional People Webinar (Video + PDF) Tags: Comfort, Energy Efficiency, Net Zero, Webinar, ZEROs 20200224
Jan 30, 2020 Events – Visit us (Booth 17) at Energy Design Expo in Duluth (2/25-26) Tags: CERV 20200130
Jan 14, 2020 Tech – Designing Exceptional Homes for Exceptional People Tags: Comfort, Ducting, Humidity, Indoor Air Quality, Report, Ventilation, ZEROs 20200114
Jan 14, 2020 Featured Article – Designing for Zero/ASHRAE Solar ZEB Article 2 Tags: Energy Efficiency, Equinox House, Net Zero, Report, Solar, ZEROs 20200114
Dec 19, 2019 Events – Free Webinar: Smart Ventilation & Air Distribution (Video+PDF) Tags: Ducting, Ventilation, Webinar 20191219
Dec 19, 2019 Events – CERV2 Smart-er Ventilation Product Demo (Video + PDF) Tags: CERV, Webinar 20191219
Dec 19, 2019 Spotlight – Acorn Glade: 2019 NAPHC Awardee! Tags: CERV, Net Zero, Passive House, Solar 20191219
Dec 16, 2019 Featured Article – Equinox Origins/ASHRAE Solar ZEB Article 1 Tags: Equinox House, Report 20191216
Nov 19, 2019 Events – Visit our booth at 2019 NAPHC in Washington DC! Tags: Passive House 20191119
Nov 19, 2019 Spotlight – Equinox House Turning 10! Tags: Equinox House 20191119
Nov 19, 2019 Featured Article – Handling Humidity Pt.4 Putting it All Together Tags: Humidity, Report, Ventilation, ZEROs 20191119
Oct 16, 2019 Events – Mechanical Systems for Passive Buildings (Chicago, Oct 16) Tags: CERV 20191016
Oct 16, 2019 Featured Article – Handling Humidity Pt.3 Methods for Managing Moisture Tags: Comfort, Humidity, Indoor Air Quality, Ventilation 20191016
Oct 16, 2019 Events – Free Webinar: Handling Humidity (Video + PDF) Tags: Comfort, Humidity, Indoor Air Quality, Ventilation, Webinar 20191016
Oct 16, 2019 Events – Free CEUs: Building Green & Beer at Founders Brewing (Oct 28) 20191016
Oct 16, 2019 Spotlight – Inter House Wins Solar Decathlon Africa!!! Tags: CERV, Net Zero, Solar 20191016
Sep 20, 2019 Featured Article – Handling Humidity Pt.2 Climate Moisture Variations Tags: Comfort, Humidity, Ventilation, ZEROs 20190920
Sep 20, 2019 News – Brand New Release: Colorfil VOC Absorbing Filters! Tags: CERV, Filters, Health, Indoor Air Quality, Ventilation 20190920
Sep 20, 2019 Tech – From CERV to CERVEZA: a Quest for Smart Beer Tags: CERV, Heat Pump 20190920
Aug 27, 2019 Events – Earn Free CEUs with the Handling Humidity Webinar (Aug 29) Tags: Comfort, Humidity, Ventilation, ZEROs 20190827
Aug 27, 2019 Featured Article – Handling Humidity Report Series Tags: Comfort, Humidity, Ventilation, ZEROs 20190827
Aug 12, 2019 News – Listen to the Building HVAC Science Podcast, ft. Ty Newell! Tags: CERV, Comfort, Health, Indoor Air Quality, Webinar 20190812
Jul 29, 2019 Events – CERV2 Smart-er Ventilation Product Demo (Aug 27, 2019) Tags: CERV, Heat Pump, Ventilation 20190729
Jul 29, 2019 Featured Article – Poor Home Maintenance = Increased Health Risks Tags: Comfort, Ducting, Energy Efficiency, Health, Humidity, Ventilation 20190729
Jul 29, 2019 Tech – Say Hello to Our New Server! 20190729
Jun 19, 2019 Featured Article – Watch out for Cranky Heaters! Tags: Energy Efficiency, Heat Pump 20190619
Jun 19, 2019 Events – Free CEU Webinar: Smart Ventilation & Air Distribution (July 10) Tags: CERV, Ducting, Energy Efficiency, Indoor Air Quality, Ventilation 20190619
Jun 19, 2019 Spotlight – Marrakech Express! CERV2 Heading to Africa! Tags: CERV, Net Zero, Solar 20190619
May 13, 2019 Featured Article – Taylor Home CERV Testimonial Tags: CERV, Comfort, Indoor Air Quality, Ventilation 20190513
May 13, 2019 Events – 7 Steps for Designing an Economical Net Zero Home (Video + PDF) Tags: Energy Efficiency, Net Zero, Solar, Ventilation, Water, Webinar, ZEROs 20190513
May 13, 2019 Tech – AeroBarrier Demonstration Tags: Energy Efficiency, Ventilation 20190513
Apr 15, 2019 Events – Indoor Air Quality Metrics Free Webinar (Apr 24, 2019) Tags: Comfort, Health, Indoor Air Quality 20190415
Apr 15, 2019 Featured Article – CERV2 Geo–Boost Tags: CERV, Energy Efficiency 20190415
Apr 15, 2019 Review – 2019 National Home Performance Conference Tags: Indoor Air Quality 20190415
Apr 15, 2019 Tech – CERV2 Sketchup Model Now Available Tags: CERV 20190415
Mar 28, 2019 News – Visit us at the Chicago 2019 National Home Performance Conference Tags: CERV 20190328
Mar 28, 2019 Featured Article – Happy Equinox, St. Patrick’s Day, and Super Moon! Tags: Equinox House 20190328
Feb 27, 2019 Events – Free CEU Webinar: Smart Ventilation & Air Distribution (Mar 12) Tags: CERV, Ducting, Energy Efficiency, Indoor Air Quality, Ventilation, Webinar 20190227
Feb 27, 2019 Featured Article – Smart Ventilation and Smart Air Distribution Reports Tags: CERV, Ducting, Energy Efficiency, Indoor Air Quality, Ventilation 20190227
Feb 27, 2019 Spotlight – El Salvador NZEB Update Tags: CERV, Net Zero, Solar 20190227
Feb 25, 2019 Events – CERV2 Smart-er Ventilation Product Demo (Video + PDF) Tags: CERV, Heat Pump, Indoor Air Quality, Ventilation, Webinar 20190225
Jan 22, 2019 Events – Smart Ventilation & Smart Air Distribution Webinar (Video & PDF) Tags: CERV, Ducting, Energy Efficiency, Indoor Air Quality, Ventilation, Webinar 20190122
Dec 26, 2018 Spotlight – Progressive Canada Tags: CERV, Net Zero, Passive House, Solar 20181226
Dec 26, 2018 News – Happy Holidays from Build Equinox! 20181226
Dec 26, 2018 Review – CERV2 at Greenbuild 2018 Tags: CERV 20181226
Nov 26, 2018 News – CERV OEM Filter Store is OPEN!!! Tags: CERV, Indoor Air Quality 20181126
Nov 19, 2018 News – Check Out Our Social Media! 20181119
Oct 24, 2018 Events – Free CEU Webinar: Duct Design & Performance (PDF Download) Tags: Ducting, Energy Efficiency, Webinar 20181024
Oct 24, 2018 Featured Article – CERV2 is UL Approved! Tags: CERV 20181024
Oct 24, 2018 News – Stop by Our Booth at Greenbuild Chicago (Free Tickets!) Tags: CERV 20181024
Oct 24, 2018 Spotlight – University of Illinois Students Visit Build Equinox Tags: CERV 20181024
Jul 23, 2018 Featured Article – Happy 10th Birthday, CERV and Sunflower! Tags: CERV, Solar 20180723
Jul 23, 2018 Spotlight – Good News from El Salvador! Tags: CERV, Net Zero, Solar 20180723
Jun 22, 2018 Tech – Installing a Ductless Mini-split Tags: Heat Pump 20180622
Jun 22, 2018 Featured Article – Mini-split Mania! Tags: Heat Pump 20180622
Apr 30, 2018 News – Now offering on-demand webinars for CEUs! 20180430
Apr 30, 2018 Events – Free CEU Webinar! (May 2, 2018) 20180430
Apr 30, 2018 Featured Article – Ductology Part 2 Tags: Ducting, Report, Ventilation 20180430
Feb 19, 2018 Review – 2018 Better Buildings by Design Conference, Flu and Colds 20180219
Feb 19, 2018 Featured Article – Hot Water! Tags: Comfort, Water 20180219
Jan 22, 2018 Events – Visit us at BuildingEnergy Boston! (March 7-9, Boston, MA) 20180122
Jan 22, 2018 Events – Efficiency Vermont Better Buildings by Design Conference (Feb 7-8) 20180122
Jan 22, 2018 Featured Article – Ductology (Part 1) Tags: Ducting, Report, Ventilation 20180122
Nov 20, 2017 Featured Article – Heat Pump (Hybrid) Clothes Dryers are Coming! Tags: Heat Pump 20171120
Oct 31, 2017 Featured Article – CERV2 Measures IAQ at NAPHC & NAPHN 20171031
Sep 25, 2017 Featured Article – Introducing CERV2 Tags: CERV 20170925
Aug 21, 2017 Events – Free CEU Webinar! (Sep 27, 2017) 20170821
Aug 21, 2017 Featured Article – Quiz 20170821
Jul 27, 2017 Events – New IAQ Metrics Webinar (Video + PDF) Tags: Health, Indoor Air Quality, Ventilation 20170727
Jul 25, 2017 Featured Article – Endotoxins: Small But Very Significant Tags: Health, Indoor Air Quality, Report, Ventilation 20170725
May 22, 2017 Events – Economical Net Zero Design Webinar (Video+PDF) Tags: Energy Efficiency, Net Zero, Webinar, ZEROs 20170522
May 22, 2017 Featured Article – Styrax Japonicus 20170522
Apr 28, 2017 Events – 7 Steps for Designing an Economical Net Zero Home (Video + PDF) Tags: Energy Efficiency, Net Zero, Webinar, ZEROs 20170428
Apr 28, 2017 Featured Article – Engineering Net Zero Homes Tags: Net Zero, ZEROs 20170428
Mar 20, 2017 Featured Article – Build Equinox Zero Plus Facility Tags: Energy Efficiency, Net Zero, Solar 20170320
Feb 14, 2017 Featured Article – February Flu Tags: Health, Indoor Air Quality, Report, Ventilation 20170214
Jan 20, 2017 Events – HRV, ERV and Smart Vent Systems, Free CEU Webinar (Feb 15) Tags: CERV, Energy Efficiency, Ventilation, Webinar 20170120
Jan 20, 2017 Events – NESEA IAQ Metrics Presentation (Mar 9, Boston, MA) Tags: Health, Indoor Air Quality 20170120
Jan 19, 2017 Featured Article – The Perfect Dust Storm Tags: Health, Indoor Air Quality, Report, Ventilation 20170119
Jan 12, 2017 Events – Efficiency Vermont Better Buildings by Design Conference (Feb 1-2) Tags: CERV 20170112
Dec 26, 2016 Featured Article – Happy Holidays from Build Equinox! 20161226
Nov 29, 2016 Featured Article – Geo-Boost Tags: CERV, Energy Efficiency 20161129
Nov 29, 2016 Spotlight – This Old Passive House Tags: Energy Efficiency, Passive House, Ventilation 20161129
Nov 29, 2016 Review – House Music 20161129
Oct 28, 2016 Featured Article – Comparing ERV, HRV, and CERV Tags: CERV, Energy Efficiency, Heat Pump, Ventilation 20161028
Oct 28, 2016 Spotlight – Net Zero Eco-House (Monticello, IL) Tags: CERV, Energy Efficiency, Net Zero, Passive House 20161028
Oct 28, 2016 Spotlight – Forty Under 40 20161028
Sep 28, 2016 Events – Free CEU Webinar (Oct 5th): Why are new Indoor Air Quality metrics needed? Tags: Health, Indoor Air Quality, Ventilation 20160928
Sep 28, 2016 Review – 2016 North American Passive House Conference Tags: Passive House 20160928
Sep 28, 2016 Featured Article – New CERV-ICE IAQ Analytics Released! Tags: CERV, Health, Indoor Air Quality 20160928
Sep 28, 2016 Spotlight – CERVs in Passive Homes, pt. 2 Tags: CERV, Passive House 20160928
Aug 18, 2016 Featured Article – Understanding the House as a System Tags: Comfort, Energy Efficiency, Humidity, Indoor Air Quality, Net Zero, Ventilation 20160818
Aug 18, 2016 Spotlight – CERVs in Passive Homes Tags: CERV, Passive House 20160818
Aug 18, 2016 Review – “What is IAQ?”, P. Ole Fanger Tags: Indoor Air Quality 20160818
Aug 18, 2016 Tech – CERV CO2/VOC Library Tags: CERV, CO2, Health, Indoor Air Quality, Report, VOC 20160818
Jul 19, 2016 Events – September North American Passive House Conference Tags: Passive House 20160719
Jul 18, 2016 News – CERV Website Tags: CERV 20160718
Jul 18, 2016 Featured Article – VERMOD CERV Report Released Tags: CERV, Energy Efficiency, Indoor Air Quality, Report 20160718
Jul 18, 2016 Review – LBNL report: “Houses are Dumb Without Smart Ventilation” Tags: Indoor Air Quality, Report, Ventilation 20160718
Jul 18, 2016 Spotlight – Professor P. Ole Fanger (1934-2006); IAQ and Comfort Pioneer Tags: Comfort, Indoor Air Quality 20160718
Jul 18, 2016 Tech Note – Airflow Calculation for Ventilation Systems Tags: Ducting, Report, Ventilation 20160718

Article Tags:

Share

Want to stay fresh with the latest knowledge on IAQ, Energy Efficiency, and Healthy Home design practices?

Want to Learn More?

Ready to get started?
Fear not, we're here to help!
Fill out the contact form below, and we'll guide you through the process.

edit_note
Step 1

Fill out the contact form.

east
mail
Step 2

We'll reach out to get more information about your project and answer questions.

east
partner_exchange
Step 3

We work together to help finalize the design and options.

east
local_shipping
Step 4

Get your CERV and start breathing fresh, healthy air!

infoWe work with a variety of customers: whether you're looking for an installer recommendation, have an installer of your own, or even want to do everything yourself...we've got you covered!
Occupation (select all that apply)
How did you find out about us? (select all that apply)
Other Website:
Attended a Webinar:
Met us at a Conference:
Word of Mouth / Recommended by:
Other: