Volatile Organic Compounds, or VOCs, are gaseous, reactive chemicals in the air we breathe. Excessive VOC levels reduce productivity, degrade sleep, and cause acute and long term health problems. Active VOC management in our indoor environments is essential for keeping humans healthy and productive.

Build Equinox healthy Indoor Air Quality Standard (IAQS) recommends keeping “total” VOCs below 125ppb (parts per billion). In this newsletter, we discuss the impact of VOCs on our health, sources of VOCs, and the basis for Build Equinox healthy IAQ Standard’s 125ppb VOC recommendation.

Build Equinox incorporated VOC sensors into our first generation CERV unit in 2010. CERV and CERV2 units have been continuously monitoring and controlling VOCs in homes throughout all North American climate zones since. Build Equinox understands VOC sources, VOC dynamics, and VOCs interrelationships with other indoor air pollutants. More importantly, we know how to automatically control VOCs to maintain healthy air in buildings so that you can have the peace-of-mind to enjoy life.

VOC Background

VOCs are a complex soup of gaseous chemicals present in the air we breathe. Some VOCs are bad, some are benign, and some are good. The smell of spring flowers, a pine forest, and Nature’s other pleasant odors are VOCs we identify with fresh, healthy air. Odors accompanying wildfire smoke, a paper mill, or other less pleasant smells trigger our brains into a stressful condition that impacts our health whether or not an odorous VOC is harmful.

Humans have difficulty detecting harmful VOC levels in indoor environments because our olfactory sense is attuned to high concentration “events”, attracting us to delicious food or repelling us from impending danger (smoke). Our olfactory sense acclimatizes to indoor air, causing us to become “nose blind” that further limits our ability to judge air quality.

Today’s VOC sensors detect VOC concentrations well below our sense of smell, allowing us to monitor and control air quality based on human health. Building occupants rather than other chemicals should be the primary contributor to indoor VOC concentrations. Other VOC sources add to those produced by our bodies. Some of these sources are intentionally created, such as fragrances and essential oils, some are due to our activities such as cooking and cleaning, and some are not related to human or human activities. Other VOC sources may be due to our selection choices of household furnishings, cleansers, etc, or they may be from sources over which we have no control such as outside air pollution.

VOC characterization is complex, but understandable. More than 200 VOC chemicals are emitted by a human placed in a room. Build Equinox has established a rational, consistent set of air quality guidelines centered around human pollutant emissions. That is, our CO2 standard (CO2<800ppm) and VOC standard (VOCs<125ppb) are not independently derived, but are linked through expected levels of human CO2 and VOC emissions. Build Equinox particulate mass and particulate count recommended levels are similarly linked to human CO2 and VOC levels as we will discuss in next month’s newsletter article.

VOCs impact our productivity and sleep quality, which have important economic consequences. Our previous article discusses economic impacts of sick days and productivity in terms of CO2 concentration, however, VOCs are a primary factor causing these effects. CO2 has been used to correlate productivity and sleep because CO2 sensing technology is older than VOC sensing technologies.

Health impacts of specific VOC chemicals are also important for the following reasons:

Acute, short term (1 hour) concentrations that cause health distress
Longer term (8 hour workday) exposure concentrations that cause health distress
Continuous exposure concentration levels that result in health issues
Probability of developing cancer due to integrated exposure to an inhalable chemical

Risk assessment procedures of a particular chemical, such as formaldehyde, a common component of building materials and furnishings, are available for estimating health impacts. We will not discuss the computational procedures in this article, but refer interested readers to California’s excellent Office Environmental Health Hazard Assessment (OEHHA) “Air Toxics Hot Spots Program” guide and appendices. Also, OEHHA’s acute, 8 hour and chronic (long term) Reference Exposure Limits (REL) table is a quick resource for finding up-to-date information on health affecting chemicals. We will discuss OEHHA and ASHRAE recommended formaldehyde chronic exposure limits relative to Build Equinox IAQ Standard in this article.

VOC emission rates due to humans, human activities, and other sources, such as formaldehyde in furnishings and outdoor air pollution, are described below. We combine these VOC emission sources together and demonstrate how Build Equinox’s recommended 125ppb VOC IAQ Standard provides a basis for designing ventilation systems. Finally, we discuss the importance of combined CO2 and VOC air quality monitoring and provide illustrative examples for low occupant density (residences) and high occupant density (classrooms) situations.

Human VOC Emissions

A sterile, stainless steel enclosure with pure, sanitized air flowing through it will become filled with hundreds of VOC compounds as soon as a human is placed in the enclosure. Wang and co-authors placed four people in such a chamber to examine human and human-related VOC production (“Emission Rates of Volatile Organic Compounds from Humans”, N Wang, L Ernle, G Bekö, P Wargocki, and J Williams, Environ. Sci. Technol. 2022, 56, 4838−4848).

The humans were clean and wearing clean clothes provided by the investigators. Experiments were conducted with participants wearing shorts and short sleeve shirts in order to expose bare skin. Other experiments were conducted with participants wearing long pants and long-sleeve shirts for comparison to bare skin emission tests. Some test subjects were old, some were young, and some in between. Temperature, humidity and ozone impacts were also examined.

Wang and co-workers found an average VOC emission of 2180µg/h-person (+/- 620 µg/h-person) without ozone. Most VOC emissions were from exhaled breath. Variations of VOC output occurred due to clothing (long/short dress), age, and comfort conditions. The most significant variation was from ozone which more than doubled VOC emissions due to skin oil reactions with ozone producing volatile chemical compounds. Moderate ozone concentrations of 37ppb, about half of EPA’s 70ppb upper limit, were used in the experiment. With elevated temperature, shorts and short sleeves, and ozone, human VOC emissions exceeded 6000µg/h-person.

Tang and co-authors (“Volatile Organic Compound Emissions from Humans Indoors”, X Tang, P K Misztal, W W Nazaroff, and A H Goldstein, Environ. Sci. Technol. 2016, 50, 12686−12694) conducted a similar experiment in a classroom on the UC Berkeley campus. The authors similarly found human breath exhalation to be the dominate source of VOC emissions. The authors noted that an incredible 1840 human VOC compounds from human body fluids have been identified.

Tang, et al, found an average of 6250µg/h-person from their classroom experiments, similar to the ozone cases of Wang, et al’s more closely controlled experiments. Personal care products, hygiene and clothing are likely sources of elevated VOC emissions in Tang, et al’s classroom environment. Tang, et al did not monitor ozone so its potential impact is unknown but likely much lower than in Wang’s experiment.

Average total VOC emission rate for Tang, et al classroom experiments was 580mg/h, with 57% from students (331mg/h). Tang, et al experiments occurred in an urban environment (Berkeley CA), which elevated classroom VOCs and accounted for 35% of classroom VOCs (203mg/h). Indoor VOC sources accounted for 8% of measured VOCs (46mg/h). 18 class periods with 27 to 67 students and an average class size of 53 students were evaluated. Fresh air ventilation was held constant at 1970cfm for all experiments.

Analysis of Tang, et al’s experimental data indicates that students elevated classroom VOCs by 44ppb, followed by 27ppb of VOCs brought in with “fresh air” ventilation, and 6ppb contributed by non-student VOC sources in the classroom (furnishings, cleansers, miscellaneous debris) for a total of 77ppb. Formaldehyde is not among detected human VOC emissions. In addition, formaldehyde was not detected in either outdoor air or indoor non-human VOC emissions.

Assuming a human metabolic rate of 0.7 (similar to sleeping, as many students do in college lectures), an average student body weight of 150 pounds per student (guesstimate), 53 students per class, and the classroom’s measured ventilation air flow (1970cfm), we find an average classroom CO2 level of 550ppm in line with the experiment’s results.

We will return to Tang, et al’s classroom experiment with examples that demonstrate how Build Equinox IAQ Standard coupled with smart ventilation incorporating CO2 and VOC control combines to save ventilation energy while automatically maintaining a healthy classroom environment.

Other VOC Emission Sources

High Occupant Density Situations – Classrooms:

Non-human sources of VOCs are important to include when determining VOC concentrations in an indoor space. Ventilation and infiltration air from the outside ambient contribute VOCs to a building’s interior, and VOCs emitted by non-human sources within the indoor space increase VOC concentrations. The two sources must be treated differently. Outdoor VOCs elevate an indoor space’s VOC concentration by a level equal to the outdoor ambient VOC concentration level, similar to outdoor ambient average CO2 concentration elevating indoor CO2 concentration by 400ppm. Non-human, indoor VOC emission sources, similar to human VOC emissions, are diluted as ventilation and infiltration air flows increase.

Tang, et al found an indoor VOC emission rate of 46mg/h and an outdoor VOC contribution of 203mg/h flowing into the classroom with ventilation air. Both contributions are important for determination of total VOC loading and VOC concentration in the classroom space. Relative to the classroom ventilation air flow (1970cfm), the indoor VOC emission source added 6ppb to the VOC concentration while ventilation air increased indoor VOC concentration by 27ppb. If ventilation air flow is decreased by 50%, the indoor VOC source would elevate classroom VOC concentration by 12ppb, while the outdoor contribution to VOC concentration stays constant at 27ppb. The 50% decrease of ventilation air would also double student VOC concentration contribution to 88ppb for a total classroom VOC concentration of 127ppb. We will keep this in mind as we consider how to apply Build Equinox IAQ Standard for sizing ventilation systems.

Low Occupant Density Situations – Residences:

A California study (“Indoor air quality in 24 California residences designed as high-performance homes”, B Less, N Mullen, B Singer, and I Walker, Science and Technology for the Built Environment (2015) 21, 14–24) found average formaldehyde concentrations of 20µg/m3 (16ppb) indoors and 4µg/m3 (3ppb) outdoors for 24 recently renovated homes in the Berkeley CA area. The homes averaged 2100sqft with average normal ACH (air changes per hour) of 0.3/h for an estimated average ventilation and infiltration air flow of 84cfm assuming a ceiling height of 8ft. Total indoor VOC concentrations were not reported for the homes, however, our focus is on formaldehyde as it is a non-human indoor and outdoor source of VOC pollution.

Applying a mass balance to formaldehyde indoor and outdoor concentration levels relative to ventilation and infiltration air flow, we find an average emission rate of 4.1mg/h of formaldehyde inside the California homes. ASHRAE 62.1 ventilation standards and California OEHHA disagree on acceptable, long term formaldehyde exposure levels. California’s current REL (Reference Level Exposure) for formaldehyde is 9µg/m3 (7ppb) while ASHRAE 62.1 lists 35µg/m3 (28ppb).

Interestingly, ASHRAE 62.1-2022 references California’s older 2004 REL standard as its reference. If that leaves you confused and perhaps less trusting of today’s ventilation standards, that’s just fine, because they are confusing. The important thing to know is that we can do something about it: purchase formaldehyde-free materials! More about this in the next section. The important point here is our estimate of 4.1mg/h of formaldehyde inside typically constructed homes, and its impact on a home’s VOC level and required ventilation.

A study by Francisco and co-authors examined IAQ before and after weatherization of 71 homes in Illinois and Indiana (“Ventilation, indoor air quality, and health in homes undergoing weatherization”, P. W. Francisco, D. E. Jacobs, L. Targos, S. L. Dixon, J. Breysse, W. Rose, S. Cali, Indoor Air 2017; 27: 463–477). Roughly half of the homes were sealed to a level based on ASHRAE 62-1989 infiltration ventilation. The other group of homes used mechanical ventilation in addition to infiltration to meet the higher ventilation requirements of ASHRAE 62.2-2010.

Focusing on the 37 homes weatherized, sealed and adjusted to ASHRAE 62.2-2010 ventilation levels, Francisco, et al reports a change from 41cfm (pre-weatherization, infiltration only ventilation) to 79cfm (post-weatherization with mechanical ventilation providing an average 60cfm to the reduced infiltration). CO2 levels decreased from 936ppm to 787ppm from pre- to post-weatherization conditions. Total VOCs dropped from 204ppb to 142ppb, with formaldehyde decreasing from 26ppb to 21ppb. These homes had a total of 37 adults and 52 children for a total of 89 home occupants (2.4 occupants per homes, similar to average US home occupancy).

Francisco, et al reported home occupant health survey information before and after weatherization. Weatherization activities included repairing moisture problems such as condensation leaks, pipe sweating, and other sources of moisture that create mold and other dampness-related health issues in addition to improved ventilation.

Reductions in children health problems included: headaches (31%), hay fever (5%), respiratory allergy (8%), eczema/skin allergy (13%), and asthma (2%). Reductions in adult health problems included: sinusitis (12%), hay fever (8%), chronic bronchitis (8%), and needing help handling routine needs (11%). The significant drops in several categories are indicative of the power of improved ventilation. We note that these homes have natural gas heat and cooking appliances. Elimination of indoor gas combustion products from indoor air would further reduce indoor VOC concentrations and improve health issues such as asthma.

Regarding formaldehyde contributions to indoor VOC concentrations, similar mass balance analyses as described for the California homes estimates 4.1mg/h of formaldehyde emissions for pre-weatherization and 6.3mg/h of formaldehyde emissions for post-weatherization. As commented by Francisco, et al, the authors had no control over weatherization material selections, resulting in formaldehyde infused weatherization materials (eg, OSB, oriented strand board). Fortunately, improved ventilation in the homes counteracted the 50% increased formaldehyde emission rate.

Unfortunately, many weatherization projects are occurring today without ventilation improvements. If ventilation was not enhanced in these homes, reduced infiltration-based ventilation would only be 20cfm, or 25% of the 79cfm enhanced ventilation level. Formaldehyde concentrations would be quadrupled to 80ppb, far exceeding acute formaldehyde levels (45ppb).

Other non-human VOC emissions can be handled in a similar manner. VOC emission rates can be converted to VOC concentrations levels, and added together with other VOC emissions. Formaldehyde is perhaps the most concerning non-human VOC source due to its abundance in today’s products. Other VOC sources such as fragrances, essential oils (see Figure 1), cleansers, personal care products, solvents, glues, paints, and many other chemicals may also be important, however many of these can be altered as one observes how VOC concentrations in their indoor spaces are impacted.

Fragrances can significantly elevate VOCs. Are they healthy? The answer may be in the mind of the beholder as opinions vary from “think before you stink” preferences to “essential oils for health” preferences. Anger and mental stress caused by dislike of fragrances or restriction from using fragrances may be more detrimental to one’s health.

Additional VOC Considerations

In last month’s article on carbon dioxide (CO2) concentration, we stated that we do not know whether CO2 at low concentrations has a direct impact on our health or is primarily a surrogate indicator of air quality. CO2 produced from human respiration and from indoor combustion (eg, gas cooking) is strongly correlated to VOCs and particulates produced by humans and their activities.

CO2 monitoring is not a substitute for VOC management! Both CO2 and VOCs must be monitored for effective indoor pollutant management. Either CO2 or VOCs (or particulates) will periodically dominate air quality. When CO2 and VOCs are both dominated by human emissions, we expect to find CO2 < 800ppm and total VOCs < 125ppb when adequate fresh air is delivered to an indoor space. An investigation of non-human VOC sources should be conducted when indoor VOC concentrations are significantly greater than expected from human emissions. If VOC concentrations stay elevated while CO2 drops during occupant absence periods, something other than human and human activity are elevating VOCs, such as off gassing of furnishings (eg, formaldehyde emission), an open container of volatile chemicals (paint, cleansers, solvents), air fragrances, etc.

Gas cooking produces CO2 at a greater rate than VOCs in relation to human CO2/VOC emissions. Unfortunately, gas cooking elevates both CO2 and VOCs significantly, with a single stove burner releasing as much CO2 as five humans. Cooking style (eg, frying versus a simmering stew) impacts pollutant emissions, and may increase VOCs emissions relative to CO2. In all electric homes, VOCs from cooking are produced with no CO2 production. An effective kitchen ventilation system will manage VOCs and prevent infusion of cooking odors into a home’s furnishings.

Natural gas and propane are reactive VOCs, readily detected by CERV and CERV2 VOC sensors. CERV/CERV2 units have detected gas leaks from leaky gas appliances. Figure 2 shows data from CERV-ICE (CERV/CERV2 online dashboard) for a new home with a leaky gas clothes dryer fitting. Fortunately, CERV and CERV2 units automatically switch to fresh air ventilation, as seen by the extended ventilation (green shading) period in Figure 2, as gas concentrations increased, helping to keep the natural gas diluted. VOC sensors detect gas concentrations well below odor detection levels, requiring plumbers, HVAC installers, and appliance installers to use electronic “snoopers” to find leaky fittings and faulty appliance components.

In another example, elevated VOCs in a home renovation project were tracked to the CERV unit’s fresh air inlet. The inlet was installed above contaminated soil where a fuel oil tank had been removed. Indoor VOCs increased in the home whenever the CERV operated in fresh air mode, indicating an outdoor source of pollutants. Relocation of the CERV2’s fresh air inlet away from the fuel oil contaminated soil resolved the problem. Without VOC sensing, home occupants would never have known they were bringing polluted air into their home. CO2 sensors are blind to VOCs and no one in the home could “smell” the contaminated air, but it was contaminated!

New home in 2014 with high VOC levels after gas appliances installed in early July prior to occupancy. High VOCs relative to CO2 indicated a significant non-human VOC source. A leaky clothes dryer gas connection was discovered and repaired July 8. VOCs dropped to level comparable to CO2 as family moved into the home a few days later, indicating human occupants were the primary source of CO2 and VOCs emissions. This plot is taken from the CERV-ICE (CERV-Intelligently Controlled Environment) dashboard for CERV and CERV2 owners.

Some of our early CERV units were installed in Vermod’s first four production homes constructed in 2013 (scroll down Vermod’s homepage and watch “John and Anne’s Story” to see what a difference a decent home can make in someone’s life). During shakedown testing at Vermod’s White River Junction facility, air quality was identical in three homes while the fourth continually exhibited high VOCs, resulting in excess fresh air venting.

If the four unoccupied homes were built with identical materials and processes, why would the CERV unit in one home continually indicate high VOC levels? CERV units were new to the market in 2013, although we had units operating in the field since 2010. Suspicion revolved around the CERV unit and our new VOC sensing technology. Is this new technology reliable? Can we trust it?

Our online monitoring capability allowed us to see that the VOC sensor seemed to be working properly. Indoor VOCs would drop in the problem home during fresh air ventilation as expected. VOCs in the problem home would inexplicably climb during recirculation mode while VOCs in the other 3 homes stayed low.

Someone finally remembered that one of the four formaldehyde-free, Formica countertops was damaged during delivery. The replacement countertop was supposed to be formaldehyde free, but was not! The CERV’s VOC sensor was correct after all. There was no odor nor observable difference among the countertops. Replacing the offending countertop with a formaldehyde free countertop made the difference….an important difference that would not have been determined without VOC sensing!

Making Smart CO2 and VOC Control Real - Residence and Classroom IAQ Examples

Two examples, one for a home and another for a classroom demonstrate how Build Equinox IAQ Standard coupled with smart ventilation as implemented by CERV ventilation systems maintains healthy air and simultaneously excels in energy efficiency in comparison to today’s inefficient, constant ventilation flow systems.

Residence Ventilation Example (low occupant density situation):

Assume we have a new, all-electric 2500sqft home, sealed to 1ACH50 with 4 bedrooms and 3 occupants. The occupants are home for 2/3 of the day (16 hours). According to ASHRAE 62.2-2022, the home requires 113cfm of continuous ventilation. Infiltration adds an average of 17cfm to the mechanical ventilation system for a constant air flow of 130cfm. It is important to note that sometimes infiltration adds no additional air flow, and other times it adds quite a bit, depending on wind speed and indoor/outdoor temperature difference.

As an alternative to constant flow ventilation, implementing CERV2 smart ventilation with CO2 and VOC air quality control, the homeowner sets the CERV2 CO2 setpoint to 800ppm and VOC setpoint to 125ppb (note, we have scaled VOC setpoints to human CO2 on the CERV2 controls, so a setting of 800ppm for VOCs is also used, indicating a VOC level of 125ppb). We neglect transient effects, but the interested reader should review our Smart Ventilation report and Smart Air Distribution report in which a sophisticated, 5 minute time stepping simulation model with real weather data compares annual air quality and energy performance of constant flow ventilation (ASHRAE 62.2) and smart ventilation (CERV/CERV2) operation.

We assume the occupants have an average 1Met activity level (8 hours of sleep with 0.7Met, and 8 hours of activity with 1.3Met) during their 16 hours in the home. Assuming the average weight of the home occupants to be 150 pounds, we can determine that the home’s required air flow for maintaining 800ppm CO2 during house occupancy is 62cfm. Infiltration provides 17cfm as discussed previously, for a smart ventilation air flow rate of 45cfm during occupancy. The house is occupied for 2/3 of a day, for a daily average of 30cfm of fresh air flow, resulting in a fresh air ventilation flow that is less than 25% of ASHRAE constant flow ventilation. And that saves a lot of energy!

Before discussing how CERV2 smart ventilation also maintains better air quality than the higher, constant air flow ventilation systems, let’s consider VOC ventilation needs. As we previously discussed, a reasonable human VOC emission rate is 6250µg/h-person. If we assume the homeowners did an excellent job selecting no/low VOC materials for their home and have negligible non-human VOC sources, and that outdoor air has negligible VOCs, the ventilation rate required to maintain indoor VOCs below 125ppb would be 40cfm. In comparison to fresh air ventilation for managing CO2, we see that it dominates over VOCs, requiring 62cfm (with 45cfm from the smart ventilation system and 17cfm from infiltration).

Ventilation needs can change significantly from house-to-house. If a formaldehyde infused material (eg, flooring) with 10mg/h of formaldehyde emissions was substituted into the home’s construction, coupled with cooking VOCs released at 15mg/h, we would find VOC ventilation needs increase to 92cfm, greater than 62cfm required to maintain CO2 at 800ppm. Note that continuous off gassing by furnishings require some level of fresh air ventilation as VOCs continual build up during unoccupied periods while no/low VOC furnishings do not require any ventilation to keep VOCs in control.

We finish up this example by discussing how smart ventilation also provides better IAQ control than constant flow, one-and-done ventilation. One might think the much higher flow, constant ventilation system also has better IAQ than the much lower ventilation flow of the smart system, but that is not the case. The constant flow ventilation system is very, very inefficient in using fresh air to benefit the home’s occupants.

Imagine the house has 8 fresh air zones (4 bedrooms, family room, fitness room, dining room, kitchen, den), and that fresh air is evenly divided among these rooms. Fresh air delivered to each room works its way to nearby exhaust return ducts, such as in bathrooms, mudroom, kitchen, and laundry. We will assume that infiltration is evenly added to the fresh air supply, but that is never the case in reality….where infiltration occurs and where you live are generally two different places.

The constant flow ventilation system’s 130cfm is divided into 8 ducts delivering 16cfm to each of the 8 zones. Let’s assume all three occupants are in the den, which increases in CO2 to 2000 to 3000ppm within a fairly short time. VOCs increase to over 300ppb due to human VOC emissions. 114cfm, or 88% of the constant ventilation fresh air flow delivered to unoccupied rooms flows to the nearest exhaust register without ever benefiting a human in the house.

The CERV2 smart ventilation system operates in a much different manner. Although it may only be adding 45cfm of fresh air into the house during occupied periods, it typically operates at 200cfm. More than 80% of the time the CERV2 is operating in recirculation mode, which allows the CERV2 to move fresh air “stored” in the home’s unoccupied areas to the occupied areas. Fresh air is never wasted! Recirculation mode is essential in all homes because it is needed for removing indoor particulates generated indoors by occupants and our activities. In one-and-done ventilation systems without recirculation, particulates and contagions build up to unhealthy levels. As homes become larger and more complex (more rooms and zones), adding zone dampers and wireless occupancy and IAQ sensors can trigger the CERV2 to open and close fresh air supply and exhaust dampers in order to deliver fresh air and remove polluted air where the need is greatest.

Classroom Ventilation Example (high occupant density situation):

We return to Tang, et al’s classroom situation relative to its operation and Build Equinox’s IAQ Standard’s CO2 and VOC recommended levels. The classroom at UC Berkeley is typical of many classrooms with constant ventilation flow. More commercial spaces are adding CO2 to ventilation systems, however CO2 alone will be unable to detect unhealthy VOC conditions.

The classroom’s 1970cfm fresh air ventilation resulted in 550ppm CO2 and 77ppb VOCs with 53 students in the room. Converting the ventilation system to a variable speed fan and modulating its speed to meet Build Equinox’s IAQ Standard will deliver significant fan energy and comfort conditioning energy savings while keeping classroom occupants healthy. During low/no occupancy periods, the ventilation system would turn down to very low flow, sufficient for assessing room IAQ comfort conditions, addressing variations in IAQ and comfort as needed.

For the classroom to maintain VOCs at 125ppb with 53 students with Tang, et al’s outdoor and indoor emission levels, 1012cfm of air flow is required. To maintain the classroom at 800ppm CO2 requires 770cfm of fresh air. In this case, VOCs dominate ventilation air flow rate requirements. Note that if outdoor VOC concentration was negligible instead of the urban environment’s 27ppb outdoor VOCs, fresh air ventilation would drop to 795cfm, similar to CO2 ventilation needs.

The smallest class had 26 students, which requires 560cfm to maintain VOCs at 125ppb, and 380cfm to manage CO2 at 800ppm. The largest class with 67 students requires 1250cfm to maintain 125ppb VOC concentration and 970cfm to maintain 800ppm CO2 concentration. Without outdoor VOCs and no non-human VOC emissions in the classroom, 340cfm would be needed for the small class and 880cfm is needed for the large class to maintain 125ppb VOC concentration.

Summary

VOCs are important to control in our indoor environments. Build Equinox has formulated its healthy IAQ Standard based on human pollutant emissions. All indoor occupied spaces will become polluted due to pollutant emissions by its occupants. Ideally, human occupants are the primary, if not the only source of pollutant emissions. When humans are the dominant source of pollutant emissions, our IAQ Standard predicts similar ventilation levels for maintaining CO2 and VOCs at healthy levels.

When other sources add to human pollutant emissions, our IAQ Standard provides a straightforward path for determining how much ventilation is needed to keep CO2 and VOC pollutants within a heathy range. Whichever pollutant has the higher ventilation air flow requirement is the ventilation level that should be used.

Active, smart control of ventilation with CO2 and VOC sensors does not waste fresh air as in constant flow, one-and-done systems. Smart ventilation more effectively maintains excellent indoor air quality as well as much more energy efficient. Applying smart ventilation to all indoor environments will form a protective cover significantly decreases the spread of contagions, reduces sick days and absenteeism, increases productivity and sleep quality, and provides enormous economic benefits to all income levels and age groups.

Build Equinox IAQ Standard is based on health in contrast to today’s “edge of sickness” ventilation standards. The gap between our healthy air quality standard and today’s ventilation standards is significant. The energy cost difference for healthy air is less than 2 cents per hour per person in harsh climates without energy recovery. Isn’t your health and the health of people around you worth 2 cents per hour? We know it is!


Related Articles:
Healthy Indoor Air Quality Standards: Carbon Dioxide (CO2)
Healthy Indoor Air Quality Standards: Particulates (PC0.3 and PM10)
Healthy Indoor Air Quality Standards: Carbon Monoxide and Radon

Filter
DateTitle
Sep 25, 2024 Tech – Early Airborne Infection Detection and Alert System 20240925
Sep 25, 2024 Spotlight – Heart of the Building (Video): John Avenson Residential Renovation Project 20240925
Aug 28, 2024 Events – Energy and Efficiency with Emily Podcast ft. Matt Blomquist and Ty Newell Tags: Comfort, Net Zero, New Construction 20240828
Aug 19, 2024 Spotlight – CERV-1000 Medical Clinic Visit Tags: CERV 1000, Renovation, Ventilation 20240819
Aug 15, 2024 Featured Article – Healthy Air Training is Important for Olympic Champions and the Rest of Us Tags: Health, Indoor Air Quality, Particulates 20240815
Jul 25, 2024 Events – “The Weekly Investment Podcast” feat. Ty Newell Tags: Comfort, Health 20240725
Jul 25, 2024 Tech – Positive Pressure: Flow Balancing of Duct Networks Tags: CERV 1000, Ducting 20240725
Jun 20, 2024 Tech – It is Artificial, but is it Intelligent? Tags: Indoor Air Quality 20240620
Jun 20, 2024 Featured Article – Positive Pressure: Prepare Yourself for Wildfire Season! Tags: Indoor Air Quality, Particulates 20240620
May 26, 2024 Events – Free CEU Webinar: What’s up with the Taylorville High, Net Zero, Pretty Good House Student Build? (June 26th) Tags: Net Zero, New Construction, Webinar 20240526
May 26, 2024 Spotlight – Taylorville High School / Pretty Good House Status Update 6: Wood Fiber Insulation and Steel Roofing Tags: Net Zero, New Construction 20240526
May 26, 2024 Featured Article – All in the Family (Coulliard Solar Foundation CERV-1000 Installation) Tags: CERV 1000, Solar 20240526
Apr 26, 2024 Events – Free CEU Webinar: Happy Boolo LEED & Zero Energy Renovation Home Tour (May 1st) Tags: Renovation, Webinar 20240426
Apr 26, 2024 News – University of Illinois and Build Equinox Particulate Research Published Tags: Particulates, Report 20240426
Apr 26, 2024 Spotlight – Taylorville High School / Pretty Good House Status Update 5: Robust & Smart Ventilation and Comfort Conditioning System Design for High Performance Homes Tags: Comfort, Net Zero, New Construction 20240426
Mar 22, 2024 Spotlight – Lakeside Net Zero LEED Platinum Passive House Tags: Net Zero, New Construction, Passive House 20240322
Mar 22, 2024 Featured Article – Breathing New Life: CERV2 Retrofits in Metropolitan Milwaukee Homes Tags: CERV, Indoor Air Quality, Renovation 20240322
Feb 29, 2024 Featured Article – Colorado Public Radio interview with CERV Homeowner John Avenson 20240229
Feb 28, 2024 Spotlight – Taylorville High School / Pretty Good House Status Update 4: Manual D (Duct Design) Tags: Ducting, New Construction 20240228
Jan 30, 2024 Featured Article – Count on the CERV-1000 to Keep Classrooms Healthy and Comfortable in Extreme Cold Weather Tags: CERV 1000, Health, Indoor Air Quality 20240130
Dec 20, 2023 Spotlight – Taylorville High School PGH Update 3: Manual J Load Calculations Tags: Comfort, Energy Efficiency, New Construction 20231220
Dec 20, 2023 Featured Article – Don’t Carbonize People to De-carbonize Buildings! Tags: Energy Efficiency 20231220
Nov 15, 2023 Spotlight – Taylorville High School / Pretty Good House Status Update 2: Energy and Comfort Tags: Comfort, Energy Efficiency, New Construction 20231115
Nov 15, 2023 Featured Article – Distillery North Leading the Charge to Meet ASHRAE 241 Tags: Renovation 20231115
Oct 20, 2023 Featured Article – Building a Strong Foundation: Taylorville High School Pretty Good House Project Tags: New Construction 20231020
Oct 3, 2023 Events – Free Video: An All-in-One Solution for Creating Healthy, Comfortable and Energy Efficient Classrooms Tags: CERV 1000, Health, Indoor Air Quality, Webinar 20231003
Sep 26, 2023 Featured Article – CERV-1000 Creates a Healthy, Productive, Comfortable, Decarbonized and Energy Efficient Classroom! Tags: CERV 1000, Health, Indoor Air Quality 20230926
Sep 26, 2023 Spotlight – Taylorville High School / Pretty Good House Collaboration Project Tags: New Construction 20230926
Sep 26, 2023 Event – Better Building Ventilation: Demand Control & Conditioning – Free CEUS (Sep 27) Tags: CERV, Indoor Air Quality, Webinar 20230926
Sep 26, 2023 Event – Maine Indoor Air Quality Council: IAQ and Energy 2023 (Portland, ME, Oct 30) Tags: Conference, Indoor Air Quality 20230926
Sep 26, 2023 Event – Illinois Association of School Boards: Joint Annual Conference (Chicago, IL, Nov 17-19) Tags: CERV 1000, Conference 20230926
Jul 26, 2023 Analysis – Where the Wildfire Smoke Goes (Understanding Particulate Management) Tags: Particulates 20230726
Jul 26, 2023 Featured Article – World’s Healthiest Classroom? CERV-1000 Installed and Ready for Action! Tags: CERV 1000, Indoor Air Quality 20230726
Jun 27, 2023 Featured Article – IAQ Standards Summary & Comparison Tags: CO2, Indoor Air Quality, Particulates, VOC 20230627
Jun 27, 2023 Breaking News! – ASHRAE Standard 241 “Control of Infectious Aerosols” Approved Tags: ASHRAE, Health, Indoor Air Quality 20230627
Jun 27, 2023 Spotlight – Brixham Hat Trick: Creating Healthy, Energy Efficient and Sustainable Schools in Maine’s Challenging Climate Tags: Indoor Air Quality, Renovation 20230627
May 30, 2023 Featured Article – Healthy Indoor Air Quality Standards: Carbon Monoxide & Radon Tags: Indoor Air Quality 20230530
May 30, 2023 Tech: ASHRAE 241P – The Beginning of a Healthy Air Revolution? Tags: ASHRAE, Health, Indoor Air Quality 20230530
May 30, 2023 Spotlight – University of Wyoming Solar Decathlon Team Wins 1st Place in Comfort and Environmental Quality with the CERV2! Tags: Comfort, New Construction, Solar Decathlon 20230530
Apr 28, 2023 Spotlight – Better Building by Design & NESEA: Barnstorming New England Tags: Conference 20230428
Apr 27, 2023 Introducing the CERV–1000 – Automated IAQ & Comfort Control for Classrooms, Restaurants, and Other High Occupant Density Spaces. Tags: CERV 1000 20230427
Apr 27, 2023 Featured Article – Healthy Indoor Air Quality Standards: Particulates (PC0.3 and PM10) Tags: Indoor Air Quality, Particulates 20230427
Mar 27, 2023 Featured Article – Healthy Indoor Air Quality Standards: Volatile Organic Compounds (VOCs) Tags: Indoor Air Quality, VOC 20230327
Feb 27, 2023 Events – Creating Healthy, Decarbonized Classrooms (Building Energy Boston, Mar 29) Tags: CERV 1000, Conference 20230227
Feb 27, 2023 Events – Better Buildings by Design (VT, Apr 5-6) Tags: Conference 20230227
Feb 27, 2023 Education – The Foundation for A Sustainable Future: Wellesley Public School “House Unplugged” Project 20230227
Feb 27, 2023 Featured Article – Healthy Indoor Air Quality Standards: Carbon Dioxide (CO2) Tags: CO2, Indoor Air Quality 20230227
Jan 26, 2023 News – What’s New in IAQ Tags: CO2, Indoor Air Quality, Particulates, VOC 20230126
Jan 26, 2023 Spotlight – Pipsqueak Passive House Makes a Big Noise Tags: New Construction, Passive House 20230126
Jan 26, 2023 Featured Article – Build Equinox Announces Healthy Indoor Air Quality Standard for the New Year! Tags: CO2, Indoor Air Quality, Particulates, VOC 20230126
Dec 30, 2022 Featured Article – Tis the Season to be Jolly? Ventilation, Inflammation and Mojo Tags: Health 20221230
Dec 30, 2022 News – Optimism for a New Year! 20221230
Nov 29, 2022 Featured Article – Fresh Air Ventilation Requirements for Pets Tags: Indoor Air Quality 20221129
Nov 29, 2022 Opinion – Are We Moving Too Fast to a Sustainable Future?  NO! Tags: Energy Efficiency 20221129
Oct 26, 2022 Vox: Our Buildings are Making Us Sick Tags: Health, Indoor Air Quality 20221026
Oct 21, 2022 Events – Visit Us at PhiusCon 2022 (Chicago, October 26-28)! Tags: Conference, Passive House 20221021
Oct 21, 2022 Tech – High SEER A/C: Higher Ratings at the Expense of Comfort Tags: Comfort, Dehumidification, Energy Efficiency, Heat Pump, Humidity 20221021
Oct 21, 2022 Featured Article – We Have Smelled the Polluters, and They are Us! Tags: CO2, Indoor Air Quality, VOC 20221021
Sep 30, 2022 Featured Article – ASHRAE (finally) Clarifies Ventilation Standard 62 IS NOT an Indoor Air Quality Standard Tags: ASHRAE, Indoor Air Quality 20220930
Sep 30, 2022 Tech – Smoking Gun: Fomite Aerosol Hypothesis Tags: Particulates 20220930
Aug 22, 2022 New Product – Level Up Your Particulate Filtration with MERV 14! Tags: Filters 20220822
Aug 22, 2022 Tech – Bright Idea! Wireless Switch Drops 20220822
Aug 22, 2022 Featured Article – Getting Fit… or Getting Sick? Tags: Health, Indoor Air Quality 20220822
Jul 20, 2022 Events – 2022 ASHRAE Annual Conference Tags: ASHRAE, Conference 20220720
Jul 20, 2022 Featured Article – 10th Anniversary of The Sun Catcher’s Journey! Tags: Solar 20220720
Jun 30, 2022 Featured Article – Radiant Heating and Cooling in High Performance Homes Tags: Comfort 20220630
Jun 30, 2022 Events – Healthy IAQ & Smart Ventilation Guidelines (July 27) Tags: Indoor Air Quality, Webinar 20220630
Jun 29, 2022 Spotlight – Frank Lloyd Wright: The Wasmuth Portfolio 20220629
May 23, 2022 Featured Article – Indoor Filters are Alive! Tags: Filters, UV 20220523
May 23, 2022 Tech – CERV2 Airflow and Duct Design Tags: CERV, Ducting 20220523
May 21, 2022 Events – Healthy IAQ & Smart Vent Guidelines (Video + PDF) Tags: Indoor Air Quality, Webinar 20220521
Apr 27, 2022 The Radon Puzzle – Smart Ventilation and Filtration Impacts on Radon Tags: Radon 20220427
Apr 27, 2022 Tech – New Pure Carbon Filters with 3x Carbon! Tags: Filters 20220427
Mar 28, 2022 Tech – CERV-UV: Ultimate Ultraviolet! Tags: CERV, UV 20220328
Mar 28, 2022 Review – Geothermal Alliance of Illinois Conference 20220328
Mar 28, 2022 Featured Article – Introducing Victor Niño as Build Equinox Director of Business Development 20220328
Feb 22, 2022 Tech Announcement – We’re Particular About Particulates! Tags: Particulates 20220222
Feb 22, 2022 Featured Article – Exciting New CERV2 Features and Options! Tags: CERV 20220222
Jan 27, 2022 Featured Article – Efficient, Smart Bathroom Ventilation with the CERV2 Tags: Bathroom 20220127
Jan 27, 2022 Review – Attending Large Venue Events – Go Illini, beat COVID! 20220127
Jan 27, 2022 Spotlight – Vermod in the News! 20220127
Dec 22, 2021 Featured Article – Filters are More Important (and Expensive) than Energy! Tags: Filters, Particulates 20211222
Dec 22, 2021 Spotlight – Sneak Peak: TBDA Decarbonization Project 20211222
Nov 15, 2021 Events – Two Talks in One Night at ASHRAE Madison (Dec. 13, 2021, CEUs available!) Tags: Webinar 20211115
Nov 15, 2021 Featured Article – Taylor CERV2+Ducted Mini Install (2.5 Year Follow-up) Tags: CERV, Renovation 20211115
Oct 25, 2021 Events – PHMass Passive House Virtual Symposium (Nov 3, 2021) Tags: Passive House, Webinar 20211025
Oct 25, 2021 Review – The Role of Global Air Pollution in Aging and Disease, by Professor Caleb Finch Tags: Health 20211025
Oct 25, 2021 Featured Article – Sustainable Schools Create a Sustainable Future Tags: CERV 1000 20211025
Sep 30, 2021 Events – PHIUScon 2021 Presentation: Human Centric Metrics for Improving Health, Comfort and Productivity Tags: Conference, Passive House 20210930
Sep 30, 2021 Featured Article – Kitchens are Exhausting! Tags: Kitchen 20210930
Sep 29, 2021 Events – Virtual Metro Denver Green Homes Tour 20210929
Aug 17, 2021 Opinion Article – ASHRAE, You’re Making Us Sick! Tags: ASHRAE 20210817
Aug 17, 2021 Featured Article – CERV2 Smart, Integrated, Supercharged Dehumidification Tags: CERV, Dehumidification 20210817
Jul 19, 2021 Events – CERV2 Smart-er Ventilation New Features & Product Demo (Video & Slides) Tags: CERV 20210719
Jul 19, 2021 Review – 5 Steps to Net Zero Multi-family Residence Renovation: Toronto Tags: Renovation 20210719
Jul 19, 2021 Featured Article – Test Chamber Pt. 2: VOCs! Tags: VOC 20210719
May 20, 2021 Tech – It’s Springtime and Aprilaire is in the Air! Tags: Dehumidification 20210520
May 18, 2021 Featured Article – Alexa, Meet the CERV 20210518
Apr 19, 2021 Spotlight – Illinois ADAPTHAUS Wins 1st Place in Comfort & Environmental Quality Tags: Comfort, Indoor Air Quality, Solar Decathlon 20210419
Apr 19, 2021 Events – Register for Building Energy Boston (Online)! May 5-7 Tags: Conference, Webinar 20210419
Apr 19, 2021 Featured Article – Broken Clocks Work Better than Today’s Ventilation Standards Tags: ASHRAE, Indoor Air Quality 20210419
Apr 19, 2021 Events – Upcoming Online Webinars and Conferences! Tags: Conference, Webinar 20210419
Mar 11, 2021 News – New Video, Booklet, and CERV2 Smart Options! Tags: CERV 20210311
Mar 10, 2021 Spotlight – CERV Installed in the UofI ADAPTHAUS Tags: CERV, Solar Decathlon 20210310
Mar 10, 2021 Events – Re-Opening Schools and Beyond Safely Webinars (3/23, 4/21, 4/22) Tags: Webinar 20210310
Mar 10, 2021 Featured Article – Human Value: Thinking Beyond Energy Tags: Energy Efficiency, Health 20210310
Feb 26, 2021 Spotlight – Dar-Lon Chan’s Journey to Sustainable Living 20210226
Feb 26, 2021 Featured Article – Covid Safe Space Calculator Tags: Health 20210226
Jan 29, 2021 Events – Efficiency Vermont Better Buildings by Design Conference (Feb 2-4) Tags: Conference 20210129
Jan 29, 2021 Spotlight – University of Illinois ADAPTHAUS becoming Reality Tags: Solar Decathlon 20210129
Jan 29, 2021 Featured Article – CERV2 Installed in Equinox House! Tags: CERV, Equinox House 20210129
Dec 21, 2020 Spotlight – Tour Bill Spohn’s New Modular Net Zero Home (CEUs available!) Tags: CERV, New Construction 20201221
Dec 21, 2020 Special Edition – Ventilation, Vaccination, Infection, and Luck. Covid-19 and the New Year Tags: Health 20201221
Dec 21, 2020 Featured Article – AWE: Air, Water, Energy Tags: Energy Efficiency, Indoor Air Quality, Water 20201221
Nov 17, 2020 Events – CERV2 Smart-er Ventilation Product Demo (Video + PDF) Tags: CERV, Webinar 20201117
Nov 16, 2020 Spotlight – New Lungs for a 101-Year-Old Home Pt.3: Heat Pump Water Heater! Tags: Renovation, Water 20201116
Nov 15, 2020 Featured Article – Equinox Meets the Needs / ASHRAE Solar ZEB Article 12 Tags: ASHRAE, Equinox House 20201115
Nov 12, 2020 Special Edition – Stay Safe this Holiday Season! Tags: Health 20201112
Oct 29, 2020 Spotlight – New Lungs for a 101-Year-Old Home Pt.2: Total HVAC Replacement! Tags: CERV, Comfort, Heat Pump, Renovation 20201029
Oct 28, 2020 Featured Article – Equinox House Performance / ASHRAE Solar ZEB Article 10 Tags: ASHRAE, Equinox House 20201028
Sep 22, 2020 Events – Michigan Residential Net Zero Energy Conference (Oct 20-22) Tags: Conference 20200922
Sep 22, 2020 News – CERV-UV Now Available for New Orders! Tags: CERV, UV 20200922
Sep 22, 2020 News – CERV-ICE Now in the iOS and Android App Stores! Tags: CERV 20200922
Sep 22, 2020 Featured Article – Solar Collection & Use / ASHRAE Solar ZEB Article 10 Tags: ASHRAE, Equinox House, Solar 20200922
Aug 17, 2020 Special Edition – Build Equinox Groundbreaking Research into COVID 19 Tags: Health 20200817
Aug 17, 2020 Events – SEDAC Webinar: Considerations, Best Practices, and Energy Implications for Reopening Critical Community Facilities in the Pandemic (Aug 18, 2020) Tags: Webinar 20200817
Aug 17, 2020 Featured Article – Comfort Conditioning & Indoor Air Quality / ASHRAE Solar ZEB Article 9 Tags: ASHRAE, Comfort, Equinox House, Indoor Air Quality 20200817
Aug 17, 2020 News – Building Science Podcast: “Ventilation & Virus Transmission Prevention” Tags: Health, Webinar 20200817
Aug 14, 2020 News – New HVAC School Podcast: “Advanced Ventilation w/ CERV2” (Watch/Listen) Tags: CERV, Webinar 20200814
Aug 12, 2020 Events – Free CEU Webinar: Can Building Science Help Us Slow COVID-19? (Sep 2, 2020) Tags: Health, Webinar 20200812
Jul 10, 2020 Special Edition – Covid-19 Update: Airborne Means AIRBORNE! Tags: Health 20200710
Jul 10, 2020 Featured Article – Appliances Power EVs / ASHRAE Solar ZEB Article 8 Tags: ASHRAE, Energy Efficiency, Equinox House 20200710
Jun 29, 2020 Events – Free New Webinar: Guidelines for Protecting Against COVID-19 (PDF + Slides) Tags: Health, Webinar 20200629
Jun 25, 2020 Featured Article – Designing a Thermally Massive Home/ASHRAE Solar ZEB Article 7 Tags: ASHRAE, Equinox House 20200625
Jun 25, 2020 Special Edition – Covid19 Status Report: We are at the Beginning of the Pandemic, Not the End Tags: Health 20200625
May 29, 2020 Spotlight – CERV Retrofit: New Lungs for a 101-Year-Old Home Tags: CERV, Renovation 20200529
May 29, 2020 Special Edition – Covid19 Status Report: Guidelines for Homes & Businesses Tags: Health 20200529
May 29, 2020 Featured Article – Ground Heat Transfer/ASHRAE Solar ZEB Article 6 Tags: ASHRAE, Equinox House 20200529
Apr 16, 2020 Events – Free CEU Webinar: Covid-19 Characteristics, Transmission, and Control (April 29th) Tags: Health, Webinar 20200416
Apr 16, 2020 Special Edition – Battling the Spread of Covid-19 Tags: Health, Report 20200416
Apr 16, 2020 Featured Article – Infiltration & Sealing/ASHRAE Solar ZEB Article 5 Tags: Energy Efficiency, Equinox House, Net Zero, Report 20200416
Apr 16, 2020 Spotlight – New Projects: 1930s CERV Retrofit & Mitsubishi Hyperheat Tags: CERV, Energy Efficiency, Heat Pump, Ventilation 20200416
Mar 13, 2020 Featured Article – Light and Delight/ASHRAE Solar ZEB Article 4 Tags: Comfort, Energy Efficiency, Equinox House, Solar 20200313
Mar 10, 2020 News – CERV Voted One of the Top 16 Coolest Things Made in Illinois! Tags: CERV 20200310
Mar 5, 2020 Special Edition – Fighting COVID-19 with Fresh Air Tags: Health, Indoor Air Quality, Report, Ventilation 20200305
Feb 24, 2020 Featured Article – Walls and Roof/ASHRAE Solar ZEB Article 3 Tags: Equinox House, Net Zero, Report, ZEROs 20200224
Feb 24, 2020 Tech – Magic-Box Mechanicals Tags: CERV, Comfort, Heat Pump, Ventilation 20200224
Feb 24, 2020 Events – Designing Exceptional Homes for Exceptional People Webinar (Video + PDF) Tags: Comfort, Energy Efficiency, Net Zero, Webinar, ZEROs 20200224
Jan 30, 2020 Events – Visit us (Booth 17) at Energy Design Expo in Duluth (2/25-26) Tags: CERV 20200130
Jan 14, 2020 Tech – Designing Exceptional Homes for Exceptional People Tags: Comfort, Ducting, Humidity, Indoor Air Quality, Report, Ventilation, ZEROs 20200114
Jan 14, 2020 Featured Article – Designing for Zero/ASHRAE Solar ZEB Article 2 Tags: Energy Efficiency, Equinox House, Net Zero, Report, Solar, ZEROs 20200114
Dec 19, 2019 Events – Free Webinar: Smart Ventilation & Air Distribution (Video+PDF) Tags: Ducting, Ventilation, Webinar 20191219
Dec 19, 2019 Events – CERV2 Smart-er Ventilation Product Demo (Video + PDF) Tags: CERV, Webinar 20191219
Dec 19, 2019 Spotlight – Acorn Glade: 2019 NAPHC Awardee! Tags: CERV, Net Zero, Passive House, Solar 20191219
Dec 16, 2019 Featured Article – Equinox Origins/ASHRAE Solar ZEB Article 1 Tags: Equinox House, Report 20191216
Nov 19, 2019 Events – Visit our booth at 2019 NAPHC in Washington DC! Tags: Passive House 20191119
Nov 19, 2019 Spotlight – Equinox House Turning 10! Tags: Equinox House 20191119
Nov 19, 2019 Featured Article – Handling Humidity Pt.4 Putting it All Together Tags: Humidity, Report, Ventilation, ZEROs 20191119
Oct 16, 2019 Events – Mechanical Systems for Passive Buildings (Chicago, Oct 16) Tags: CERV 20191016
Oct 16, 2019 Featured Article – Handling Humidity Pt.3 Methods for Managing Moisture Tags: Comfort, Humidity, Indoor Air Quality, Ventilation 20191016
Oct 16, 2019 Events – Free Webinar: Handling Humidity (Video + PDF) Tags: Comfort, Humidity, Indoor Air Quality, Ventilation, Webinar 20191016
Oct 16, 2019 Events – Free CEUs: Building Green & Beer at Founders Brewing (Oct 28) 20191016
Oct 16, 2019 Spotlight – Inter House Wins Solar Decathlon Africa!!! Tags: CERV, Net Zero, Solar 20191016
Sep 20, 2019 Featured Article – Handling Humidity Pt.2 Climate Moisture Variations Tags: Comfort, Humidity, Ventilation, ZEROs 20190920
Sep 20, 2019 News – Brand New Release: Colorfil VOC Absorbing Filters! Tags: CERV, Filters, Health, Indoor Air Quality, Ventilation 20190920
Sep 20, 2019 Tech – From CERV to CERVEZA: a Quest for Smart Beer Tags: CERV, Heat Pump 20190920
Aug 27, 2019 Events – Earn Free CEUs with the Handling Humidity Webinar (Aug 29) Tags: Comfort, Humidity, Ventilation, ZEROs 20190827
Aug 27, 2019 Featured Article – Handling Humidity Report Series Tags: Comfort, Humidity, Ventilation, ZEROs 20190827
Aug 12, 2019 News – Listen to the Building HVAC Science Podcast, ft. Ty Newell! Tags: CERV, Comfort, Health, Indoor Air Quality, Webinar 20190812
Jul 29, 2019 Events – CERV2 Smart-er Ventilation Product Demo (Aug 27, 2019) Tags: CERV, Heat Pump, Ventilation 20190729
Jul 29, 2019 Featured Article – Poor Home Maintenance = Increased Health Risks Tags: Comfort, Ducting, Energy Efficiency, Health, Humidity, Ventilation 20190729
Jul 29, 2019 Tech – Say Hello to Our New Server! 20190729
Jun 19, 2019 Featured Article – Watch out for Cranky Heaters! Tags: Energy Efficiency, Heat Pump 20190619
Jun 19, 2019 Events – Free CEU Webinar: Smart Ventilation & Air Distribution (July 10) Tags: CERV, Ducting, Energy Efficiency, Indoor Air Quality, Ventilation 20190619
Jun 19, 2019 Spotlight – Marrakech Express! CERV2 Heading to Africa! Tags: CERV, Net Zero, Solar 20190619
May 13, 2019 Featured Article – Taylor Home CERV Testimonial Tags: CERV, Comfort, Indoor Air Quality, Ventilation 20190513
May 13, 2019 Events – 7 Steps for Designing an Economical Net Zero Home (Video + PDF) Tags: Energy Efficiency, Net Zero, Solar, Ventilation, Water, Webinar, ZEROs 20190513
May 13, 2019 Tech – AeroBarrier Demonstration Tags: Energy Efficiency, Ventilation 20190513
Apr 15, 2019 Events – Indoor Air Quality Metrics Free Webinar (Apr 24, 2019) Tags: Comfort, Health, Indoor Air Quality 20190415
Apr 15, 2019 Featured Article – CERV2 Geo–Boost Tags: CERV, Energy Efficiency 20190415
Apr 15, 2019 Review – 2019 National Home Performance Conference Tags: Indoor Air Quality 20190415
Apr 15, 2019 Tech – CERV2 Sketchup Model Now Available Tags: CERV 20190415
Mar 28, 2019 News – Visit us at the Chicago 2019 National Home Performance Conference Tags: CERV 20190328
Mar 28, 2019 Featured Article – Happy Equinox, St. Patrick’s Day, and Super Moon! Tags: Equinox House 20190328
Feb 27, 2019 Events – Free CEU Webinar: Smart Ventilation & Air Distribution (Mar 12) Tags: CERV, Ducting, Energy Efficiency, Indoor Air Quality, Ventilation, Webinar 20190227
Feb 27, 2019 Featured Article – Smart Ventilation and Smart Air Distribution Reports Tags: CERV, Ducting, Energy Efficiency, Indoor Air Quality, Ventilation 20190227
Feb 27, 2019 Spotlight – El Salvador NZEB Update Tags: CERV, Net Zero, Solar 20190227
Feb 25, 2019 Events – CERV2 Smart-er Ventilation Product Demo (Video + PDF) Tags: CERV, Heat Pump, Indoor Air Quality, Ventilation, Webinar 20190225
Jan 22, 2019 Events – Smart Ventilation & Smart Air Distribution Webinar (Video & PDF) Tags: CERV, Ducting, Energy Efficiency, Indoor Air Quality, Ventilation, Webinar 20190122
Dec 26, 2018 Spotlight – Progressive Canada Tags: CERV, Net Zero, Passive House, Solar 20181226
Dec 26, 2018 News – Happy Holidays from Build Equinox! 20181226
Dec 26, 2018 Review – CERV2 at Greenbuild 2018 Tags: CERV 20181226
Nov 26, 2018 News – CERV OEM Filter Store is OPEN!!! Tags: CERV, Indoor Air Quality 20181126
Nov 19, 2018 News – Check Out Our Social Media! 20181119
Oct 24, 2018 Events – Free CEU Webinar: Duct Design & Performance (PDF Download) Tags: Ducting, Energy Efficiency, Webinar 20181024
Oct 24, 2018 Featured Article – CERV2 is UL Approved! Tags: CERV 20181024
Oct 24, 2018 News – Stop by Our Booth at Greenbuild Chicago (Free Tickets!) Tags: CERV 20181024
Oct 24, 2018 Spotlight – University of Illinois Students Visit Build Equinox Tags: CERV 20181024
Jul 23, 2018 Featured Article – Happy 10th Birthday, CERV and Sunflower! Tags: CERV, Solar 20180723
Jul 23, 2018 Spotlight – Good News from El Salvador! Tags: CERV, Net Zero, Solar 20180723
Jun 22, 2018 Tech – Installing a Ductless Mini-split Tags: Heat Pump 20180622
Jun 22, 2018 Featured Article – Mini-split Mania! Tags: Heat Pump 20180622
Apr 30, 2018 News – Now offering on-demand webinars for CEUs! 20180430
Apr 30, 2018 Events – Free CEU Webinar! (May 2, 2018) 20180430
Apr 30, 2018 Featured Article – Ductology Part 2 Tags: Ducting, Report, Ventilation 20180430
Feb 19, 2018 Review – 2018 Better Buildings by Design Conference, Flu and Colds 20180219
Feb 19, 2018 Featured Article – Hot Water! Tags: Comfort, Water 20180219
Jan 22, 2018 Events – Visit us at BuildingEnergy Boston! (March 7-9, Boston, MA) 20180122
Jan 22, 2018 Events – Efficiency Vermont Better Buildings by Design Conference (Feb 7-8) 20180122
Jan 22, 2018 Featured Article – Ductology (Part 1) Tags: Ducting, Report, Ventilation 20180122
Nov 20, 2017 Featured Article – Heat Pump (Hybrid) Clothes Dryers are Coming! Tags: Heat Pump 20171120
Oct 31, 2017 Featured Article – CERV2 Measures IAQ at NAPHC & NAPHN 20171031
Sep 25, 2017 Featured Article – Introducing CERV2 Tags: CERV 20170925
Aug 21, 2017 Events – Free CEU Webinar! (Sep 27, 2017) 20170821
Aug 21, 2017 Featured Article – Quiz 20170821
Jul 27, 2017 Events – New IAQ Metrics Webinar (Video + PDF) Tags: Health, Indoor Air Quality, Ventilation 20170727
Jul 25, 2017 Featured Article – Endotoxins: Small But Very Significant Tags: Health, Indoor Air Quality, Report, Ventilation 20170725
May 22, 2017 Events – Economical Net Zero Design Webinar (Video+PDF) Tags: Energy Efficiency, Net Zero, Webinar, ZEROs 20170522
May 22, 2017 Featured Article – Styrax Japonicus 20170522
Apr 28, 2017 Events – 7 Steps for Designing an Economical Net Zero Home (Video + PDF) Tags: Energy Efficiency, Net Zero, Webinar, ZEROs 20170428
Apr 28, 2017 Featured Article – Engineering Net Zero Homes Tags: Net Zero, ZEROs 20170428
Mar 20, 2017 Featured Article – Build Equinox Zero Plus Facility Tags: Energy Efficiency, Net Zero, Solar 20170320
Feb 14, 2017 Featured Article – February Flu Tags: Health, Indoor Air Quality, Report, Ventilation 20170214
Jan 20, 2017 Events – HRV, ERV and Smart Vent Systems, Free CEU Webinar (Feb 15) Tags: CERV, Energy Efficiency, Ventilation, Webinar 20170120
Jan 20, 2017 Events – NESEA IAQ Metrics Presentation (Mar 9, Boston, MA) Tags: Health, Indoor Air Quality 20170120
Jan 19, 2017 Featured Article – The Perfect Dust Storm Tags: Health, Indoor Air Quality, Report, Ventilation 20170119
Jan 12, 2017 Events – Efficiency Vermont Better Buildings by Design Conference (Feb 1-2) Tags: CERV 20170112
Dec 26, 2016 Featured Article – Happy Holidays from Build Equinox! 20161226
Nov 29, 2016 Featured Article – Geo-Boost Tags: CERV, Energy Efficiency 20161129
Nov 29, 2016 Spotlight – This Old Passive House Tags: Energy Efficiency, Passive House, Ventilation 20161129
Nov 29, 2016 Review – House Music 20161129
Oct 28, 2016 Featured Article – Comparing ERV, HRV, and CERV Tags: CERV, Energy Efficiency, Heat Pump, Ventilation 20161028
Oct 28, 2016 Spotlight – Net Zero Eco-House (Monticello, IL) Tags: CERV, Energy Efficiency, Net Zero, Passive House 20161028
Oct 28, 2016 Spotlight – Forty Under 40 20161028
Sep 28, 2016 Events – Free CEU Webinar (Oct 5th): Why are new Indoor Air Quality metrics needed? Tags: Health, Indoor Air Quality, Ventilation 20160928
Sep 28, 2016 Review – 2016 North American Passive House Conference Tags: Passive House 20160928
Sep 28, 2016 Featured Article – New CERV-ICE IAQ Analytics Released! Tags: CERV, Health, Indoor Air Quality 20160928
Sep 28, 2016 Spotlight – CERVs in Passive Homes, pt. 2 Tags: CERV, Passive House 20160928
Aug 18, 2016 Featured Article – Understanding the House as a System Tags: Comfort, Energy Efficiency, Humidity, Indoor Air Quality, Net Zero, Ventilation 20160818
Aug 18, 2016 Spotlight – CERVs in Passive Homes Tags: CERV, Passive House 20160818
Aug 18, 2016 Review – “What is IAQ?”, P. Ole Fanger Tags: Indoor Air Quality 20160818
Aug 18, 2016 Tech – CERV CO2/VOC Library Tags: CERV, CO2, Health, Indoor Air Quality, Report, VOC 20160818
Jul 19, 2016 Events – September North American Passive House Conference Tags: Passive House 20160719
Jul 18, 2016 News – CERV Website Tags: CERV 20160718
Jul 18, 2016 Featured Article – VERMOD CERV Report Released Tags: CERV, Energy Efficiency, Indoor Air Quality, Report 20160718
Jul 18, 2016 Review – LBNL report: “Houses are Dumb Without Smart Ventilation” Tags: Indoor Air Quality, Report, Ventilation 20160718
Jul 18, 2016 Spotlight – Professor P. Ole Fanger (1934-2006); IAQ and Comfort Pioneer Tags: Comfort, Indoor Air Quality 20160718
Jul 18, 2016 Tech Note – Airflow Calculation for Ventilation Systems Tags: Ducting, Report, Ventilation 20160718

Article Tags:

Share

Want to stay fresh with the latest knowledge on IAQ, Energy Efficiency, and Healthy Home design practices?

Want to Learn More?

Ready to get started?
Fear not, we're here to help!
Fill out the contact form below, and we'll guide you through the process.

edit_note
Step 1

Fill out the contact form.

east
mail
Step 2

We'll reach out to get more information about your project and answer questions.

east
partner_exchange
Step 3

We work together to help finalize the design and options.

east
local_shipping
Step 4

Get your CERV and start breathing fresh, healthy air!

infoWe work with a variety of customers: whether you're looking for an installer recommendation, have an installer of your own, or even want to do everything yourself...we've got you covered!
Occupation (select all that apply)
How did you find out about us? (select all that apply)
Other Website:
Attended a Webinar:
Met us at a Conference:
Word of Mouth / Recommended by:
Other: